Waste Heat Identification & Utilisation: Capturing Thermal Energy from Boiling Water Tap Drain Outlets

Waste heat recovery from point-of-use boiling water appliances represents an underexplored opportunity for energy efficiency in institutional buildings. This study investigates the feasibility of recovering thermal energy from the drain outlet of a HydroTap G5 BCS60 installed in the J02 Learning Hub at the University of Sydney. Thermal camera measurements identified drain pipe surface temperatures of approximately 90°C against ambient conditions of 15–30°C, representing a temperature differential of up to 75°C. A helical baffled concentric tube heat exchanger is proposed to recover this waste heat and preheat incoming cold mains water prior to boiler entry, reducing electrical heating demand. Computational fluid dynamics simulations across four seasonal ambient temperatures demonstrated consistent heat exchanger effectiveness of 20.4–20.7%, with heat recovery ranging from 423–537 W. Economic analysis estimates annual savings of $316 and 489 kg CO₂-equivalent at 180 L/day usage, with a simple payback period of 2.8–7.6 years.

Publication Details

Journal
The Sydney Journal of Interdisciplinary Engineering
Published
2026-11-18
DOI
https://doi.org/10.30722/nc8syz13
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Waste Heat Identification & Utilisation: Capturing Thermal Energy from Boiling Water Tap Drain Outlets

1 links
The Sydney Journal of Interdisciplinary Engineering
Building Energy and Comfort Optimization
article

Waste Heat Identification & Utilisation: Capturing Thermal Energy from Boiling Water Tap Drain Outlets

article en

Abstract

Waste heat recovery from point-of-use boiling water appliances represents an underexplored opportunity for energy efficiency in institutional buildings. This study investigates the feasibility of recovering thermal energy from the drain outlet of a HydroTap G5 BCS60 installed in the J02 Learning Hub at the University of Sydney. Thermal camera measurements identified drain pipe surface temperatures of approximately 90°C against ambient conditions of 15–30°C, representing a temperature differential of up to 75°C. A helical baffled concentric tube heat exchanger is proposed to recover this waste heat and preheat incoming cold mains water prior to boiler entry, reducing electrical heating demand. Computational fluid dynamics simulations across four seasonal ambient temperatures demonstrated consistent heat exchanger effectiveness of 20.4–20.7%, with heat recovery ranging from 423–537 W. Economic analysis estimates annual savings of $316 and 489 kg CO₂-equivalent at 180 L/day usage, with a simple payback period of 2.8–7.6 years.

The Sydney Journal of Interdisciplinary EngineeringVol. 2(1)
Responsible consumption and production, Affordable and clean energy, Clean water and sanitation, Climate action
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon