A Deep Learning Framework for Retrospective Motion Detection and Conditional Correction (MDCC): Application to Multi-Gradient-Recalled Echo Quantitative MRI
Multi-echo gradient-recalled-echo (mGRE) MRI supports quantitative neuroimaging by enabling voxel-wise T2*/R2*/R2t* mapping for quantitative assessment of tissue damage and magnetic susceptibility imaging. Subject motion degrades these acquisitions by introducing inconsistencies due to phase-encoding steps collected at different head positions. Although the gradient echoes associated with a given phase-encoding line are acquired at practically the same head position, differences in contrast, signal-to-noise ratio, and B0 field-dependent phase evolution cause the resulting artifacts to appear differently across echoes and can bias downstream parametric maps. Existing learning-based retrospective correction approaches often discard complex phase information, treat multiple gradient-recalled echoes independently, and apply correction indiscriminately to both motion-corrupted and clean data. We propose Motion Detection and Conditional Correction (MDCC), a retrospective image-domain pipeline that couples a complex-input volume-level Multi-Echo Motion Detection (ME-MoD) model and a complex-valued Multi-Echo Motion Corrector (ME-MoC) in an iterative detect-correct-re-evaluate loop, where correction is invoked only on volumes flagged as motion corrupted. ME-MoD reweights each echo with a phase-preserving paired complex gate, followed by a shared residual slice encoder, and a selected volume-level aggregator. ME-MoC is a fully complex-valued, factorized U-Net with echo-axis multi-head self-attention at the bottleneck, trained with a T2*-consistency physics loss. ME-MoD attained an AUC of 0.95 and sensitivity of 0.91 on the held-out detection set. At the cohort-level analysis, ME-MoC improved downstream R2* fitting results relative to the motion-corrupted input and 2D U-Net and achieved the lowest numerical R2* root-mean-square error (RMSE) among the evaluated methods, including modest numerical improvement over baseline.
Authors
- J. H. Lewis (ORCID: https://orcid.org/0000-0002-9442-9427)
- Dmitriy A. Yablonskiy (ORCID: https://orcid.org/0000-0003-2898-8797)
- Satya V. V. N. Kothapalli (ORCID: https://orcid.org/0000-0003-0129-3442)
- Cihat Eldeniz (ORCID: https://orcid.org/0000-0002-4457-0916)
- Gulfam Saju (ORCID: https://orcid.org/0009-0007-7391-0485)
Institutions
- Washington University in St. Louis (US)
- Mallinckrodt (United States) (US)
Publication Details
- Journal
- Journal of Imaging Informatics in Medicine
- Published
- 2026-11-17
- DOI
- https://doi.org/10.1007/s10278-026-02525-7
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Institutes of Health
- National Institute on Aging