A Deep Learning Framework for Retrospective Motion Detection and Conditional Correction (MDCC): Application to Multi-Gradient-Recalled Echo Quantitative MRI

Multi-echo gradient-recalled-echo (mGRE) MRI supports quantitative neuroimaging by enabling voxel-wise T2*/R2*/R2t* mapping for quantitative assessment of tissue damage and magnetic susceptibility imaging. Subject motion degrades these acquisitions by introducing inconsistencies due to phase-encoding steps collected at different head positions. Although the gradient echoes associated with a given phase-encoding line are acquired at practically the same head position, differences in contrast, signal-to-noise ratio, and B0 field-dependent phase evolution cause the resulting artifacts to appear differently across echoes and can bias downstream parametric maps. Existing learning-based retrospective correction approaches often discard complex phase information, treat multiple gradient-recalled echoes independently, and apply correction indiscriminately to both motion-corrupted and clean data. We propose Motion Detection and Conditional Correction (MDCC), a retrospective image-domain pipeline that couples a complex-input volume-level Multi-Echo Motion Detection (ME-MoD) model and a complex-valued Multi-Echo Motion Corrector (ME-MoC) in an iterative detect-correct-re-evaluate loop, where correction is invoked only on volumes flagged as motion corrupted. ME-MoD reweights each echo with a phase-preserving paired complex gate, followed by a shared residual slice encoder, and a selected volume-level aggregator. ME-MoC is a fully complex-valued, factorized U-Net with echo-axis multi-head self-attention at the bottleneck, trained with a T2*-consistency physics loss. ME-MoD attained an AUC of 0.95 and sensitivity of 0.91 on the held-out detection set. At the cohort-level analysis, ME-MoC improved downstream R2* fitting results relative to the motion-corrupted input and 2D U-Net and achieved the lowest numerical R2* root-mean-square error (RMSE) among the evaluated methods, including modest numerical improvement over baseline.

Authors

Institutions

Publication Details

Journal
Journal of Imaging Informatics in Medicine
Published
2026-11-17
DOI
https://doi.org/10.1007/s10278-026-02525-7
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Deep Learning Framework for Retrospective Motion Detection and Conditional Correction (MDCC): Application to Multi-Gradient-Recalled Echo Quantitative MRI

J. H. Lewis, Dmitriy A. Yablonskiy, Satya V. V. N. Kothapalli, Cihat Eldeniz et al.
1 links
Journal of Imaging Informatics in Medicine
Advanced MRI Techniques and Applications
article

A Deep Learning Framework for Retrospective Motion Detection and Conditional Correction (MDCC): Application to Multi-Gradient-Recalled Echo Quantitative MRI

J. H. Lewis, Dmitriy A. Yablonskiy, Satya V. V. N. Kothapalli, Cihat Eldeniz, Gulfam Saju
article en

Abstract

Multi-echo gradient-recalled-echo (mGRE) MRI supports quantitative neuroimaging by enabling voxel-wise T2*/R2*/R2t* mapping for quantitative assessment of tissue damage and magnetic susceptibility imaging. Subject motion degrades these acquisitions by introducing inconsistencies due to phase-encoding steps collected at different head positions. Although the gradient echoes associated with a given phase-encoding line are acquired at practically the same head position, differences in contrast, signal-to-noise ratio, and B0 field-dependent phase evolution cause the resulting artifacts to appear differently across echoes and can bias downstream parametric maps. Existing learning-based retrospective correction approaches often discard complex phase information, treat multiple gradient-recalled echoes independently, and apply correction indiscriminately to both motion-corrupted and clean data. We propose Motion Detection and Conditional Correction (MDCC), a retrospective image-domain pipeline that couples a complex-input volume-level Multi-Echo Motion Detection (ME-MoD) model and a complex-valued Multi-Echo Motion Corrector (ME-MoC) in an iterative detect-correct-re-evaluate loop, where correction is invoked only on volumes flagged as motion corrupted. ME-MoD reweights each echo with a phase-preserving paired complex gate, followed by a shared residual slice encoder, and a selected volume-level aggregator. ME-MoC is a fully complex-valued, factorized U-Net with echo-axis multi-head self-attention at the bottleneck, trained with a T2*-consistency physics loss. ME-MoD attained an AUC of 0.95 and sensitivity of 0.91 on the held-out detection set. At the cohort-level analysis, ME-MoC improved downstream R2* fitting results relative to the motion-corrupted input and 2D U-Net and achieved the lowest numerical R2* root-mean-square error (RMSE) among the evaluated methods, including modest numerical improvement over baseline.

Journal of Imaging Informatics in Medicine
Washington University in St. Louis (US), Mallinckrodt (United States) (US)
National Institutes of Health, National Institute on Aging
Good health and well-being
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon