The Influence of Clinical History on the Accuracy of Fetal Weight Estimation at Term: A Prospective Study

Objective To assess whether access to obstetric and medical history affects the accuracy of clinical and ultrasonographic estimated fetal weight (EFW) at term. Methods We conducted a prospective paired observational study of singleton pregnancies at 37 + 0 to 42 + 0 weeks. A routine examiner reviewed the complete clinical history and performed clinical and ultrasonographic EFW. A second examiner, blinded to the history, exact gestational age, prior estimates, and patient-provided information, performed both assessments and then repeated them after reviewing the history. Accuracy was quantified using absolute percentage error (APE) relative to measured birthweight. The primary outcome was the within-participant difference in ultrasound APE between the blinded and routine examiners. Results Of 183 enrolled participants, 158 had complete data for all six assessments. Mean birthweight was 3,465 ± 413 g. Mean ultrasound APE was 6.11% for the blinded examiner and 6.00% for the routine examiner; the mean paired difference was 0.11 percentage points (95% bootstrap CI − 0.84 to 0.96; P=.808). Mean clinical APE was 8.02% for the blinded examiner and 6.54% for the routine examiner (difference 1.48 percentage points, 95% CI 0.47–2.68; P=.007). In exploratory within-examiner analyses, APE decreased after history review by 0.97 percentage points for clinical estimation and 0.58 percentage points for ultrasonography. Among infants weighing at least 4,000 g, the blinded-versus-routine ultrasound difference was 1.30 percentage points (95% CI − 0.73 to 3.63; P=.275). Conclusion In term singleton pregnancies, access to clinical history did not significantly influence ultrasound-based EFW accuracy. Differences observed in clinical and exploratory within-examiner analyses were small and unlikely to be clinically meaningful.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-18
DOI
https://doi.org/10.21203/rs.3.rs-11389189/v1
Primary Topic
Maternal and Perinatal Health Interventions
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

The Influence of Clinical History on the Accuracy of Fetal Weight Estimation at Term: A Prospective Study

Nitzan Dana Sela, Daniel Malchi, Ido Izhaki, Adi Dayan‐Schwartz et al.
1 links
Research Square
Maternal and Perinatal Health Interventions
preprint

The Influence of Clinical History on the Accuracy of Fetal Weight Estimation at Term: A Prospective Study

Nitzan Dana Sela, Daniel Malchi, Ido Izhaki, Adi Dayan‐Schwartz, Noah Zafran, Noga Shachor, Khadeje Seh, Gali Garmi
preprint en

Abstract

Objective To assess whether access to obstetric and medical history affects the accuracy of clinical and ultrasonographic estimated fetal weight (EFW) at term. Methods We conducted a prospective paired observational study of singleton pregnancies at 37 + 0 to 42 + 0 weeks. A routine examiner reviewed the complete clinical history and performed clinical and ultrasonographic EFW. A second examiner, blinded to the history, exact gestational age, prior estimates, and patient-provided information, performed both assessments and then repeated them after reviewing the history. Accuracy was quantified using absolute percentage error (APE) relative to measured birthweight. The primary outcome was the within-participant difference in ultrasound APE between the blinded and routine examiners. Results Of 183 enrolled participants, 158 had complete data for all six assessments. Mean birthweight was 3,465 ± 413 g. Mean ultrasound APE was 6.11% for the blinded examiner and 6.00% for the routine examiner; the mean paired difference was 0.11 percentage points (95% bootstrap CI − 0.84 to 0.96; P=.808). Mean clinical APE was 8.02% for the blinded examiner and 6.54% for the routine examiner (difference 1.48 percentage points, 95% CI 0.47–2.68; P=.007). In exploratory within-examiner analyses, APE decreased after history review by 0.97 percentage points for clinical estimation and 0.58 percentage points for ultrasonography. Among infants weighing at least 4,000 g, the blinded-versus-routine ultrasound difference was 1.30 percentage points (95% CI − 0.73 to 3.63; P=.275). Conclusion In term singleton pregnancies, access to clinical history did not significantly influence ultrasound-based EFW accuracy. Differences observed in clinical and exploratory within-examiner analyses were small and unlikely to be clinically meaningful.

Research Square
Technion – Israel Institute of Technology (IL), Emek Medical Center (IL), University of Haifa (IL)
Good health and well-being
Maternal and Perinatal Health Interventions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon