The effect of a hybrid PV-BESS system on voltage level, transient processes and power balance in a single-phase residential grid: a 2 × 2 factorial analysis under non-linear load conditions

Abstract. Rooftop PV systems, some with batteries, are spreading quickly in Uzbek households. We studied how such a system affects the supply voltage using a switching-level MATLAB/Simulink model of a hybrid PV-BESS system (3053 W PV array, 120 V / 100 Ah Li-ion battery, 400 V DC link) on a 220 V, 50 Hz single-phase grid. Irradiance (1 or 1000 W/m²) and load (5 kW linear, with or without a capacitor-filtered rectifier) formed a 2 × 2 design, and the PCC voltage was assessed per IEC 61000-4-30 against GOST 32144-2013 and GOST 13109-97. PV operation raised the PCC voltage by 1.48 percentage points on average, while the rectifier lowered it by 0.69 points. The effects were additive and matched the grid-impedance voltage drop within 0.02 V, which places the +5 % and +10 % levels at about 6.7 and 14 kW of export. In steady state the frequency deviation was below 10⁻⁶ Hz and the voltage fluctuation at most 0.0023 %, no dips or swells occurred, and MPPT efficiency was 99.13 %. The weak points were elsewhere. At start-up the DC-link voltage overshot to 455.9 V (14 %), and because the PI controller has no anti-windup, it settled in 0.27–0.29 s with PV instead of 0.055 s. The energy management system (EMS) computes the battery current from the nominal 120 V instead of the actual ≈128 V. As a result, the battery supplied 6.6 % more power than planned, the inverter output exceeded 5 kW and, with PV in operation, the bridge current came within 1.7–2.0 A of its 35 A limit.

Authors

Institutions

Publication Details

Journal
Journal of Mathematical Models and Methods in Engineering
Published
2026-11-16
DOI
https://doi.org/10.66901/yfdnkc07
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The effect of a hybrid PV-BESS system on voltage level, transient processes and power balance in a single-phase residential grid: a 2 × 2 factorial analysis under non-linear load conditions

Ilxomjon Siddikov, Mansurjon Abdujalilov
Journal of Mathematical Models and Methods in Engineering
Photovoltaic System Optimization Techniques
article

The effect of a hybrid PV-BESS system on voltage level, transient processes and power balance in a single-phase residential grid: a 2 × 2 factorial analysis under non-linear load conditions

Ilxomjon Siddikov, Mansurjon Abdujalilov
article en

Abstract

Abstract. Rooftop PV systems, some with batteries, are spreading quickly in Uzbek households. We studied how such a system affects the supply voltage using a switching-level MATLAB/Simulink model of a hybrid PV-BESS system (3053 W PV array, 120 V / 100 Ah Li-ion battery, 400 V DC link) on a 220 V, 50 Hz single-phase grid. Irradiance (1 or 1000 W/m²) and load (5 kW linear, with or without a capacitor-filtered rectifier) formed a 2 × 2 design, and the PCC voltage was assessed per IEC 61000-4-30 against GOST 32144-2013 and GOST 13109-97. PV operation raised the PCC voltage by 1.48 percentage points on average, while the rectifier lowered it by 0.69 points. The effects were additive and matched the grid-impedance voltage drop within 0.02 V, which places the +5 % and +10 % levels at about 6.7 and 14 kW of export. In steady state the frequency deviation was below 10⁻⁶ Hz and the voltage fluctuation at most 0.0023 %, no dips or swells occurred, and MPPT efficiency was 99.13 %. The weak points were elsewhere. At start-up the DC-link voltage overshot to 455.9 V (14 %), and because the PI controller has no anti-windup, it settled in 0.27–0.29 s with PV instead of 0.055 s. The energy management system (EMS) computes the battery current from the nominal 120 V instead of the actual ≈128 V. As a result, the battery supplied 6.6 % more power than planned, the inverter output exceeded 5 kW and, with PV in operation, the bridge current came within 1.7–2.0 A of its 35 A limit.

Journal of Mathematical Models and Methods in EngineeringVol. 3(1)
Tashkent Institute of Irrigation and Agricultural Mechanization Engineers (UZ)
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon