A prospective assessment of the utility of the clock test in the diagnosis od dementia

Background: The clock drawing test (CDT) is one of the most widely used cognitive screening tools in older adults. Used for >100 years, it assumes that the person examined can use an analog clock. In the digital era, analog clock literacy among younger generations has been declining, raising questions about the long-term validity of CDT-based screening. Material and Methods: A single-centre, cross-sectional, anonymous study was conducted in 230 fifth-year medical students of Wroclaw Medical University (age: mean ± standard deviation 24.0±1.3 years, 60.9% women) in the second semester of 2025/2026. Each participant completed 2 tasks: reading 5 clock times from analog clock faces displayed for 7 seconds each, and the classic CDT – drawing a clock face showing 11:10. Responses were scored dichotomously. Wilson confidence intervals were calculated for proportions; groups were compared with Pearson’s χ² or Fisher’s exact test, with odds ratios and 95% confidence intervals. A multivariable logistic regression was also performed. Results: Under the strict criterion (numerals and hands), the clock face was drawn correctly by 218 participants (94.8%), and under the full criterion (numerals inside the circle) by 196 (85.2%). All 5 clock times were read correctly by 135 (58.7%) and ≥4 of 5 by 207 (90.0%). The most frequent single error was the reading of 01:50 (79, 34.3%); 43.0% of these errors were “02:50” and 16.5% “14:50”, together 59.5% consisting in rounding up the hour hand. Daily analog clock use was reported by 96.1%. Sex, residence, declared clock use and age were not significantly associated with 5/5 correct readings. Conclusions: A discrepancy was observed between preserved clock-face drawing and a lower proportion of fully correct time readings, with a recurring error pattern (rounding up of the hour hand). The findings are consistent with a cultural basis for these errors but, without independent cognitive assessment, cannot establish it. Med Pr Work Health Saf. 2026;77(4)

Authors

Institutions

Publication Details

Journal
Medycyna Pracy
Published
2026-11-17
DOI
https://doi.org/10.13075/mp.5893.01748
Primary Topic
Dementia and Cognitive Impairment Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A prospective assessment of the utility of the clock test in the diagnosis od dementia

Małgorzata Szymala-Pędzik, Anna Janocha, Małgorzata Izabela Sobieszczańska, Maria Rataj et al.
Medycyna Pracy
Dementia and Cognitive Impairment Research
article

A prospective assessment of the utility of the clock test in the diagnosis od dementia

Małgorzata Szymala-Pędzik, Anna Janocha, Małgorzata Izabela Sobieszczańska, Maria Rataj, Katarzyna Kożuch-Sajdak, Marta Iskra
article en

Abstract

Background: The clock drawing test (CDT) is one of the most widely used cognitive screening tools in older adults. Used for >100 years, it assumes that the person examined can use an analog clock. In the digital era, analog clock literacy among younger generations has been declining, raising questions about the long-term validity of CDT-based screening. Material and Methods: A single-centre, cross-sectional, anonymous study was conducted in 230 fifth-year medical students of Wroclaw Medical University (age: mean ± standard deviation 24.0±1.3 years, 60.9% women) in the second semester of 2025/2026. Each participant completed 2 tasks: reading 5 clock times from analog clock faces displayed for 7 seconds each, and the classic CDT – drawing a clock face showing 11:10. Responses were scored dichotomously. Wilson confidence intervals were calculated for proportions; groups were compared with Pearson’s χ² or Fisher’s exact test, with odds ratios and 95% confidence intervals. A multivariable logistic regression was also performed. Results: Under the strict criterion (numerals and hands), the clock face was drawn correctly by 218 participants (94.8%), and under the full criterion (numerals inside the circle) by 196 (85.2%). All 5 clock times were read correctly by 135 (58.7%) and ≥4 of 5 by 207 (90.0%). The most frequent single error was the reading of 01:50 (79, 34.3%); 43.0% of these errors were “02:50” and 16.5% “14:50”, together 59.5% consisting in rounding up the hour hand. Daily analog clock use was reported by 96.1%. Sex, residence, declared clock use and age were not significantly associated with 5/5 correct readings. Conclusions: A discrepancy was observed between preserved clock-face drawing and a lower proportion of fully correct time readings, with a recurring error pattern (rounding up of the hour hand). The findings are consistent with a cultural basis for these errors but, without independent cognitive assessment, cannot establish it. Med Pr Work Health Saf. 2026;77(4)

Medycyna Pracy
Wroclaw Medical University (PL)
Dementia and Cognitive Impairment Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon