Counting quanta versus linear readout for a stochastic gravitational-wave background in resonant detectors

Preprint of the manuscript submitted to Classical and Quantum Gravity, with its Supplementary Material. We compare counting of quanta with linear readout, under one likelihood-based criterion, for a stochastic gravitational-wave background in a resonant detector read through one bosonic mode. A counter does not register zero-point fluctuations: with many counts, the flat background known and the input line at the mode temperature T, an ideal frequency-resolving counter lowers the detectable strain spectral density by the known factors e^u against an amplifier at the standard quantum limit and √2 cosh u against noiseless homodyne, with u = ħω₀/2k_BT (ω₀ angular frequency). One detector must know the excess of its mode over its input line to a fraction of the background ∝ (κτ)^(−1/2) (κ linewidth, τ integration time): an ideal counter in one year on a 7.4 GHz cavity of assumed intrinsic quality factor 2 × 10^5 at 60 to 150 mK needs T known to about 10^(−6), far beyond reported calibrations. With two identical detectors of unknown backgrounds, separate counters fall behind a linear pair (to leading order for time-resolved records), while counters after a coherent combination keep the single-detector advantage; every readout needs overlapping responses, hence detectors within centimeters at GHz frequencies, and independent noises. For two such cavities with input lines at 40 mK, combined counters with demonstrated parameters, lossless optics and outputs swapping roles faster than the counters drift would lower that density 11-fold against the homodyne pair and 7.7-fold against a 4.5 dB squeezed pair with cavities at 60 mK, and 2.4- and 1.6-fold at 150 mK (physical temperatures reported for haloscope cavities in multi-tesla fields); these are ratios between readouts, not absolute sensitivities. For a 1 GHz acoustic mode with a port and an input line at its temperature, an ideal single-window counter gains 7.1 over homodyne at 10 mK and 1.5 at 40 mK, leaving a companion paper's classical shortfall unchanged. Code and data: https://doi.org/10.5281/zenodo.23915376

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-17
DOI
https://doi.org/10.5281/zenodo.24313133
Primary Topic
Pulsars and Gravitational Waves Research
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Counting quanta versus linear readout for a stochastic gravitational-wave background in resonant detectors

S. Gaudio
Zenodo (CERN European Organization for Nuclear Research)
Pulsars and Gravitational Waves Research
preprint

Counting quanta versus linear readout for a stochastic gravitational-wave background in resonant detectors

S. Gaudio
preprint en

Abstract

Preprint of the manuscript submitted to Classical and Quantum Gravity, with its Supplementary Material. We compare counting of quanta with linear readout, under one likelihood-based criterion, for a stochastic gravitational-wave background in a resonant detector read through one bosonic mode. A counter does not register zero-point fluctuations: with many counts, the flat background known and the input line at the mode temperature T, an ideal frequency-resolving counter lowers the detectable strain spectral density by the known factors e^u against an amplifier at the standard quantum limit and √2 cosh u against noiseless homodyne, with u = ħω₀/2k_BT (ω₀ angular frequency). One detector must know the excess of its mode over its input line to a fraction of the background ∝ (κτ)^(−1/2) (κ linewidth, τ integration time): an ideal counter in one year on a 7.4 GHz cavity of assumed intrinsic quality factor 2 × 10^5 at 60 to 150 mK needs T known to about 10^(−6), far beyond reported calibrations. With two identical detectors of unknown backgrounds, separate counters fall behind a linear pair (to leading order for time-resolved records), while counters after a coherent combination keep the single-detector advantage; every readout needs overlapping responses, hence detectors within centimeters at GHz frequencies, and independent noises. For two such cavities with input lines at 40 mK, combined counters with demonstrated parameters, lossless optics and outputs swapping roles faster than the counters drift would lower that density 11-fold against the homodyne pair and 7.7-fold against a 4.5 dB squeezed pair with cavities at 60 mK, and 2.4- and 1.6-fold at 150 mK (physical temperatures reported for haloscope cavities in multi-tesla fields); these are ratios between readouts, not absolute sensitivities. For a 1 GHz acoustic mode with a port and an input line at its temperature, an ideal single-window counter gains 7.1 over homodyne at 10 mK and 1.5 at 40 mK, leaving a companion paper's classical shortfall unchanged. Code and data: https://doi.org/10.5281/zenodo.23915376

Zenodo (CERN European Organization for Nuclear Research)
Pulsars and Gravitational Waves Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon