An IMU-Based Wearable Device Utilizing Error-State Kalman Filtering for Motion Capture
Inertial measurement units (IMUs) provide a portable and infrastructure-free solution for human motion capture, but accumulated integration errors lead to substantial drift during continuous motion. This paper presents a wearable device for human motion capture using wireless IMU sensing nodes and a constraint-aided error-state Kalman filtering framework. For lower-limb motion capture, three IMU nodes are placed on the pelvis and bilateral ankles to reduce the number of body-worn sensors. Zero-velocity updates are applied during detected stance phases, and biomechanical constraints are introduced to suppress inertial drift and improve motion consistency. Closed-loop walking experiments and Vicon-referenced evaluation demonstrate that the proposed device achieves a relative trajectory drift of 2.64% and an overall root-mean-square error (RMSE) of 15.334 mm, together with improved biomechanical consistency. The proposed device provides a practical solution for wearable motion capture with sparse sensor deployment.
Authors
- Liang Shan (ORCID: https://orcid.org/0009-0002-2602-4513)
- Yinhua Liu (ORCID: https://orcid.org/0000-0001-8424-1183)
Institutions
- Qingdao University (CN)
Publication Details
- Journal
- Applied Sciences
- Published
- 2026-11-17
- DOI
- https://doi.org/10.3390/app162211392
- Primary Topic
- Inertial Sensor and Navigation
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Qingdao University