Rapid Determination of Multi-VOCs in Breath using Vernier Quantum-Cascade Laser Spectroscopy

Abstract We present a fully integrated, portable spectrometer based on Vernier-tuned quantum-cascade laser, developed for real-time measurement of volatile organic compounds (VOCs) in exhaled breath. A dedicated overflow-based breath-inlet interface provides stable and reproducible sampling by minimizing gas-exchange delays and preventing water condensation, while enabling automated segmentation of diagnostically relevant phases of individual exhalations either through flow- or CO 2 -triggering. To address quantification in congested mid-infrared spectra, we developed an automated sliding-window selection algorithm based on a hierarchical search strategy. The algorithm identifies narrow spectral regions with high specificity for a target analyte and low contributions from spectral interferences, thereby reducing dependence on subjective spectral-window selection and enabling robust and reproducible procedure for quantification. The analytical workflow was validated through controlled spiking experiments with limits of quantification ranging from 6 to 200 ppb for the VOCs investigated. Real-time breath measurements in individual volunteers are presented as proof-of-concept demonstrations of the platform’s ability to monitor different breath VOCs and their temporal dynamics in complex gas matrices. The measurements include a biphasic postprandial methanol response following fruit consumption and prolonged washout of the asthma-inhaler propellant 1,1,1,2-tetrafluoroethane (HFC-134a). The high temporal resolution additionally resolves intra-breath VOC profiles, providing information on differences in the temporal behavior of endogenous and exogenously induced contributions. Overall, the combination of Vernier-QCL spectroscopy with automated spectral-window selection and controlled breath sampling provides a compact and robust approach to time-resolved multi-VOC quantification in human breath and establishes a basis for further development toward clinical breath-research applications.

Authors

Institutions

Publication Details

Journal
Journal of Breath Research
Published
2026-11-17
DOI
https://doi.org/10.1088/1752-7163/aec31d
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Rapid Determination of Multi-VOCs in Breath using Vernier Quantum-Cascade Laser Spectroscopy

Renato Zenobi, Srdjan Janni Micic, Béla Tuzson, Alexander Mœller et al.
2 links
Journal of Breath Research
Spectroscopy and Laser Applications
article

Rapid Determination of Multi-VOCs in Breath using Vernier Quantum-Cascade Laser Spectroscopy

Renato Zenobi, Srdjan Janni Micic, Béla Tuzson, Alexander Mœller, Miloš Selaković, Lukas Emmenegger
article en

Abstract

Abstract We present a fully integrated, portable spectrometer based on Vernier-tuned quantum-cascade laser, developed for real-time measurement of volatile organic compounds (VOCs) in exhaled breath. A dedicated overflow-based breath-inlet interface provides stable and reproducible sampling by minimizing gas-exchange delays and preventing water condensation, while enabling automated segmentation of diagnostically relevant phases of individual exhalations either through flow- or CO 2 -triggering. To address quantification in congested mid-infrared spectra, we developed an automated sliding-window selection algorithm based on a hierarchical search strategy. The algorithm identifies narrow spectral regions with high specificity for a target analyte and low contributions from spectral interferences, thereby reducing dependence on subjective spectral-window selection and enabling robust and reproducible procedure for quantification. The analytical workflow was validated through controlled spiking experiments with limits of quantification ranging from 6 to 200 ppb for the VOCs investigated. Real-time breath measurements in individual volunteers are presented as proof-of-concept demonstrations of the platform’s ability to monitor different breath VOCs and their temporal dynamics in complex gas matrices. The measurements include a biphasic postprandial methanol response following fruit consumption and prolonged washout of the asthma-inhaler propellant 1,1,1,2-tetrafluoroethane (HFC-134a). The high temporal resolution additionally resolves intra-breath VOC profiles, providing information on differences in the temporal behavior of endogenous and exogenously induced contributions. Overall, the combination of Vernier-QCL spectroscopy with automated spectral-window selection and controlled breath sampling provides a compact and robust approach to time-resolved multi-VOC quantification in human breath and establishes a basis for further development toward clinical breath-research applications.

Journal of Breath Research
ETH Zurich (CH), University Children's Hospital Zurich (CH), Swiss Federal Laboratories for Materials Science and Technology (CH)
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon