Label-Free Power Failure Detection in CNC Machine Tools via Cross-Domain Energy Residual Monitoring

Abstract Predictive maintenance of CNC machine tools is limited by scarce fault-labelled data and the need to commission a model separately for each machine. This paper proposes CEAD (Cross-domain Energy Anomaly Detector), a label-free framework that requires neither fault labels nor target-domain training data. CEAD trains a Fuzzy Inference System and Extreme Gradient Boosting (XGBoost) energy model exclusively on 1,000 normal-operation records from a manufacturer-provided simulation dataset and freezes it. It then deploys the frozen model on a structurally different target (AI4I 2020, a synthetic milling-machine benchmark of 10,000 samples) through a deterministic feature mapping with no learnable parameters. The absolute difference between the predicted mechanical power and the normalised actual mechanical power defines the Energy Residual Index (ERI), a scalar health indicator in source-domain-referenced watts. A percentile control limit on a short calibration window of verified normal operation sets the alert threshold, so that no stage of the framework uses fault labels. Evaluated on 9,000 held-out AI4I 2020 samples (95 Power Failure events), CEAD achieves an Area Under the Receiver Operating Characteristic Curve (AUC-ROC) = 0.9914 and, at the 95th-percentile threshold, recall = 93.7% at a false positive rate of 3.8%. It outperforms Isolation Forest, One-Class SVM, and Local Outlier Factor by at least 9.6 percentage points in AUC-ROC and misses 6 Power Failure events against 45–59 for the baselines. These results remain consistent for calibration windows as small as 500 samples. Power Failure elevates the mean ERI from 133 W to 363 W (2.72×; Mann–Whitney p < 0.001), while mechanical fault modes yield at most a moderate response (AUC-ROC ≤ 0.693). CEAD thus enables predictive maintenance deployment from manufacturer simulation data and a short verified-normal recording, without fault-labelling campaigns or per-machine model training.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2026-11-17
DOI
https://doi.org/10.1088/2631-8695/aec36c
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Label-Free Power Failure Detection in CNC Machine Tools via Cross-Domain Energy Residual Monitoring

Tran Ngoc Hoang
1 links
Engineering Research Express
Machine Fault Diagnosis Techniques
article

Label-Free Power Failure Detection in CNC Machine Tools via Cross-Domain Energy Residual Monitoring

Tran Ngoc Hoang
article en

Abstract

Abstract Predictive maintenance of CNC machine tools is limited by scarce fault-labelled data and the need to commission a model separately for each machine. This paper proposes CEAD (Cross-domain Energy Anomaly Detector), a label-free framework that requires neither fault labels nor target-domain training data. CEAD trains a Fuzzy Inference System and Extreme Gradient Boosting (XGBoost) energy model exclusively on 1,000 normal-operation records from a manufacturer-provided simulation dataset and freezes it. It then deploys the frozen model on a structurally different target (AI4I 2020, a synthetic milling-machine benchmark of 10,000 samples) through a deterministic feature mapping with no learnable parameters. The absolute difference between the predicted mechanical power and the normalised actual mechanical power defines the Energy Residual Index (ERI), a scalar health indicator in source-domain-referenced watts. A percentile control limit on a short calibration window of verified normal operation sets the alert threshold, so that no stage of the framework uses fault labels. Evaluated on 9,000 held-out AI4I 2020 samples (95 Power Failure events), CEAD achieves an Area Under the Receiver Operating Characteristic Curve (AUC-ROC) = 0.9914 and, at the 95th-percentile threshold, recall = 93.7% at a false positive rate of 3.8%. It outperforms Isolation Forest, One-Class SVM, and Local Outlier Factor by at least 9.6 percentage points in AUC-ROC and misses 6 Power Failure events against 45–59 for the baselines. These results remain consistent for calibration windows as small as 500 samples. Power Failure elevates the mean ERI from 133 W to 363 W (2.72×; Mann–Whitney p < 0.001), while mechanical fault modes yield at most a moderate response (AUC-ROC ≤ 0.693). CEAD thus enables predictive maintenance deployment from manufacturer simulation data and a short verified-normal recording, without fault-labelling campaigns or per-machine model training.

Engineering Research Express
University of Da Nang (VN), Trường Đại học Sư phạm Kỹ thuật (VN)
Đại học Đà Nẵng
Industry, innovation and infrastructure
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon