Seasonal Performance Assessment and Optimisation of a Utility-Scale Single-Axis Tracking Bifacial Photovoltaic Inverter Block in the Al-Madinah Region, Saudi Arabia, Using Multiple Analytical Tools

Utility-scale photovoltaic (PV) plants in the desert climate of Western Saudi Arabia experience high irradiance but suffer from notable energy losses from elevated module temperatures and soiling. This study evaluates a representative 1.1 MW AC inverter block from an anonymised single-axis-tracking bifacial PV plant in Al-Madinah at four seasonal operating points, employing a datasheet-based single-diode electrical model, PVsyst, and PV*SOL. Estimated cell temperatures increased from 44 °C in winter to 69 °C in summer, raising the thermal derate from 5% to 12%. PVsyst and PV*SOL produced operating-point performance ratios (PRop) of 76.8–78.3% and 79.1–83.1%, respectively. When PVsyst loss factors were applied, the single-diode model aligned with PV*SOL within 3%, except during winter, when a difference of about 11% remained. On an annual basis, PVsyst reported a PR of approximately 83% and PV*SOL 88.25%, with a grid export of 2953.8 MWh/year; these are independent estimates. The module temperature accounted for the largest loss (10.4% in PVsyst; 6.79% in PV*SOL), followed by soiling (3.0%) and mismatch (approximately 2%). Conditional scenarios based on literature coefficients indicate that front-side measures could increase winter output by about 5% (range: 3–12%) and summer output by about 7% (range: 3–17%), mainly through cleaning, anti-soiling coatings, and cable improvements. A view factor estimate of the rear-side bifacial gain, not included in the simulations, suggests an additional gain of approximately 9% for natural desert ground.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-17
DOI
https://doi.org/10.3390/en19225556
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Seasonal Performance Assessment and Optimisation of a Utility-Scale Single-Axis Tracking Bifacial Photovoltaic Inverter Block in the Al-Madinah Region, Saudi Arabia, Using Multiple Analytical Tools

Mohammed Saeid Alkahtani, Hamad H. Alqahtani, Faisal S. Alharbi, Ali Fahad A. Alaklabi et al.
4 links
Energies
Photovoltaic System Optimization Techniques
article

Seasonal Performance Assessment and Optimisation of a Utility-Scale Single-Axis Tracking Bifacial Photovoltaic Inverter Block in the Al-Madinah Region, Saudi Arabia, Using Multiple Analytical Tools

Mohammed Saeid Alkahtani, Hamad H. Alqahtani, Faisal S. Alharbi, Ali Fahad A. Alaklabi, Fahad D. Alshahrani, Jaser J. Aljohani, Salah A. Alshammari
article en

Abstract

Utility-scale photovoltaic (PV) plants in the desert climate of Western Saudi Arabia experience high irradiance but suffer from notable energy losses from elevated module temperatures and soiling. This study evaluates a representative 1.1 MW AC inverter block from an anonymised single-axis-tracking bifacial PV plant in Al-Madinah at four seasonal operating points, employing a datasheet-based single-diode electrical model, PVsyst, and PV*SOL. Estimated cell temperatures increased from 44 °C in winter to 69 °C in summer, raising the thermal derate from 5% to 12%. PVsyst and PV*SOL produced operating-point performance ratios (PRop) of 76.8–78.3% and 79.1–83.1%, respectively. When PVsyst loss factors were applied, the single-diode model aligned with PV*SOL within 3%, except during winter, when a difference of about 11% remained. On an annual basis, PVsyst reported a PR of approximately 83% and PV*SOL 88.25%, with a grid export of 2953.8 MWh/year; these are independent estimates. The module temperature accounted for the largest loss (10.4% in PVsyst; 6.79% in PV*SOL), followed by soiling (3.0%) and mismatch (approximately 2%). Conditional scenarios based on literature coefficients indicate that front-side measures could increase winter output by about 5% (range: 3–12%) and summer output by about 7% (range: 3–17%), mainly through cleaning, anti-soiling coatings, and cable improvements. A view factor estimate of the rear-side bifacial gain, not included in the simulations, suggests an additional gain of approximately 9% for natural desert ground.

EnergiesVol. 19(22)
Taif University (SA), University of Bisha (SA), Ministry of Defense (IL), Ministry of Defense (SA)
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon