Investigation of optimal placement of locking attachment plate in periprosthetic femoral fractures: a biomechanical comparative study

Aims: To investigate the biomechanical effects of proximal, diaphyseal, and dual locking attachment plate (LAP) configurations compared with a locking compression plate (LCP)-only construct in a Vancouver type C periprosthetic femoral fracture model under cyclic and monotonic loading. Methods: A cementless stem was implanted into synthetic femora to create a standardized Vancouver type C periprosthetic femoral fracture. Four constructs (n = 6 each) were evaluated: proximal LAP, diaphyseal LAP, dual LAP, and a LCP-only control. Axial cyclic loading was applied starting at 600 N with progressive increments up to 1,800 N (maximum 6,500 cycles), followed by monotonic loading to failure. Primary outcomes were cyclic load to first fracture line and monotonic failure load. Composite bone distance and fracture line locations were also assessed. Results: Cyclic load to first fracture line did not differ among constructs (all p > 0.05). Under monotonic loading, proximal LAP (mean 4,850.2 N (SD 1,026.9)) and dual LAP (mean 4,593.6 N (SD 930.3)) demonstrated higher failure loads than diaphyseal LAP (mean 3,226.1 N (SD 423.0)) and the LCP-only control (mean 3,266.7 N (SD 676.5)) (p = 0.014 to 0.042), with no significant difference between proximal and dual LAP constructs. Composite bone distance increased progressively during cyclic loading. Fracture lines clustered near the fourth hole in the proximal LAP configuration and near the second hole in the diaphyseal and dual LAP configurations. Early fatigue failure occurred in the proximal LAP (2/6), diaphyseal LAP (1/6), and control (2/6) groups, whereas no specimen failed during cyclic loading in the dual LAP group. Conclusion: This biomechanical study demonstrates that proximal and dual LAP configurations provide higher static failure strength than diaphyseal LAP or LCP-only constructs, while resistance to early cyclic fracture was similar among configurations. The absence of early fatigue failure in the dual LAP configuration indicates a mechanical advantage when anatomical placement allows.

Authors

Institutions

Publication Details

Journal
Bone and Joint Research
Published
2026-11-17
DOI
https://doi.org/10.1302/2046-3758.1511.bjr-2026-0057.r1
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Investigation of optimal placement of locking attachment plate in periprosthetic femoral fractures: a biomechanical comparative study

Muneaki Ishijima, Koki Omori, Tomonori Baba, Michael Blauth et al.
Bone and Joint Research
Orthopaedic implants and arthroplasty
article

Investigation of optimal placement of locking attachment plate in periprosthetic femoral fractures: a biomechanical comparative study

Muneaki Ishijima, Koki Omori, Tomonori Baba, Michael Blauth, Yukie Horikoshi, Yuki Nagata
article en

Abstract

Aims: To investigate the biomechanical effects of proximal, diaphyseal, and dual locking attachment plate (LAP) configurations compared with a locking compression plate (LCP)-only construct in a Vancouver type C periprosthetic femoral fracture model under cyclic and monotonic loading. Methods: A cementless stem was implanted into synthetic femora to create a standardized Vancouver type C periprosthetic femoral fracture. Four constructs (n = 6 each) were evaluated: proximal LAP, diaphyseal LAP, dual LAP, and a LCP-only control. Axial cyclic loading was applied starting at 600 N with progressive increments up to 1,800 N (maximum 6,500 cycles), followed by monotonic loading to failure. Primary outcomes were cyclic load to first fracture line and monotonic failure load. Composite bone distance and fracture line locations were also assessed. Results: Cyclic load to first fracture line did not differ among constructs (all p > 0.05). Under monotonic loading, proximal LAP (mean 4,850.2 N (SD 1,026.9)) and dual LAP (mean 4,593.6 N (SD 930.3)) demonstrated higher failure loads than diaphyseal LAP (mean 3,226.1 N (SD 423.0)) and the LCP-only control (mean 3,266.7 N (SD 676.5)) (p = 0.014 to 0.042), with no significant difference between proximal and dual LAP constructs. Composite bone distance increased progressively during cyclic loading. Fracture lines clustered near the fourth hole in the proximal LAP configuration and near the second hole in the diaphyseal and dual LAP configurations. Early fatigue failure occurred in the proximal LAP (2/6), diaphyseal LAP (1/6), and control (2/6) groups, whereas no specimen failed during cyclic loading in the dual LAP group. Conclusion: This biomechanical study demonstrates that proximal and dual LAP configurations provide higher static failure strength than diaphyseal LAP or LCP-only constructs, while resistance to early cyclic fracture was similar among configurations. The absence of early fatigue failure in the dual LAP configuration indicates a mechanical advantage when anatomical placement allows.

Bone and Joint ResearchVol. 15(11)
Innsbruck Medical University (AT), Universität Innsbruck (AT), Juntendo University (JP), Johnson & Johnson (Brazil) (BR), Johnson & Johnson K.K. (Japan) (JP)
Good health and well-being
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon