Gelatin‐Coated High‐Strength Commercial Sutures Show Antibiotic Elution With Distinct Release Kinetics: An In Vitro Study
PURPOSE: To develop a reproducible technique for coating high-strength sutures with doxycycline or vancomycin and to compare the antibiotic elution profiles of round and tape-style sutures over time in an in vitro model. METHODS: In this in vitro study, 2 round (No. 2 FiberWire [PE-R, polyethylene-core round], No. 2 ActivBraid [COL-R, collagen-integrated round]) and 2 tape-style (1.5 mm LabralTape [PE-T, polyethylene-core tape], 1.5 mm ActivBraid [COL-T, collagen-integrated tape]) sutures were dip-coated in gelatin solutions containing low (C1) or high (C2) doxycycline or vancomycin concentrations. After drying, 1-cm segments were incubated at 37°C, and daily aliquots were collected over 7 days. Antibiotic release was quantified by enzyme-linked immunosorbent assay. RESULTS: Total doxycycline and vancomycin elution ranged from 83.6 to 151.8 ng and 261.3 to 319.1 ng, respectively. Doxycycline showed first-order-like elution, with the greatest occurring during days 1 to 3. In contrast, vancomycin showed near-constant elution with minor fluctuations over time. At individual timepoints, COL-T (C1D) released more doxycycline than COL-R on days 2 and 3, whereas COL-T released more than COL-R on day 5 in C2D. COL-R (C1V, C2V) released more vancomycin than PE-R on day 5. Conversely, COL-R (C2D) released less doxycycline than PE-R on day 6. Intergroup comparisons showed that PE-T released more vancomycin in C2V versus C1V on day 3, and PE-R released more vancomycin in C1V versus C2V on day 5 and more doxycycline in C1D versus C2D on day 6. CONCLUSIONS: Coating commercial high-strength sutures with either doxycycline or vancomycin using a gelatin-based dip-coat produced measurable, but low-level, antibiotic elution over 7 days in this in vitro model. Doxycycline exhibited a release profile consistent with first-order kinetics characterized by a higher initial burst followed by tapering elution, whereas vancomycin showed a more sustained release pattern consistent with near zero-order kinetics. Among the coated constructs, COL-T sutures exhibited the greatest doxycycline elution, whereas COL-R sutures exhibited the greatest vancomycin elution relative to PE-R sutures. CLINICAL RELEVANCE: Antimicrobial coating of high-strength orthopaedic sutures enables sustained local antibiotic elution and may provide a potential strategy for reducing the early postoperative infection risk in tendon and ligament repairs.
Authors
- Caroline Fay (ORCID: https://orcid.org/0009-0008-3111-7435)
- Nicholas A. Sgaglione (ORCID: https://orcid.org/0000-0001-8340-9757)
- Kevin F. Bonner (ORCID: https://orcid.org/0000-0002-0487-5010)
- Eric V. Neufeld (ORCID: https://orcid.org/0000-0002-7247-7671)
- Apratim Maity (ORCID: https://orcid.org/0009-0008-0299-0905)
- Daniel A. Grande (ORCID: https://orcid.org/0000-0003-0760-8185)
Institutions
- Northwell Health (US)
- Feinstein Institute for Medical Research (US)
- Long Island Jewish Medical Center (US)
- Donald & Barbara Zucker School of Medicine at Hofstra/Northwell (US)
- Jordan-Young Institute (US)
Publication Details
- Journal
- Arthroscopy The Journal of Arthroscopic and Related Surgery
- Published
- 2026-11-17
- DOI
- https://doi.org/10.1002/arj.70724
- Primary Topic
- Surgical Sutures and Adhesives
- Type
- article
- Field-Weighted Citation Impact
- 0.00