Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion

Study DesignBiomechanical.ObjectivesTo compare subaxial cervical stability with a dental composite-plate construct versus lateral mass screw-rod construct.Methods6 fresh-frozen human cadaveric cervical vertebrae (C4-C7) were prepared by stripping all soft tissues. Lateral mass screw fixation was performed bilaterally with standard freehand technique. Dental composite (Filtek) was applied to lamina before placement of a custom minifragment plate. Range of motion (ROM) and rotation to failure testing was performed using a robotic testing system (SimVITRO). Wilcoxon ranked sum test with Benjamini-Hochberg correction was used to compare results with significance set to p<0.05.ResultsThe screw-rod construct (5.1±4.0 deg) and composite-plate construct (4.5±3.2 deg) significantly decreased flexion-extension ROM relative to native state (8.1±1.7 deg, p<0.05). Only the composite-plate construct (2.7±1.9 deg) significantly decreased lateral bending ROM relative to native state (4.7±2.5 deg, p<0.05). Both the screw-rod construct (7.0±4.3 deg) and composite-plate construct (5.7±3.7 deg) significantly decreased axial rotation ROM relative to native state (9.9±5.2 deg, p<0.05). Composite-plate also decreased axial rotation ROM relative to screw-rod, while both constructs had comparable ROM in flexion-extension and lateral bending. Flexion to failure for the composite-plate construct was 7.1 ± 1.7 N-m. Mechanism of failure was the composite cracking off bone.ConclusionScrew-rod and composite-plate constructs significantly decrease ROM compared to the native state and are comparable in stiffness. Failure of composite-plate occurs with composite cracking off undamaged bone surface. A strategy utilizing composite fixation may offer a reasonable alternative to screws for subaxial stabilization.

Authors

Institutions

Publication Details

Journal
Global Spine Journal
Published
2026-11-17
DOI
https://doi.org/10.1177/21925682261504976
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion

Yun‐Da Li, Somayeh H. Ahmad, Calvin K. Chan, Serena S. Hu et al.
Global Spine Journal
Spinal Fractures and Fixation Techniques
article

Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion

Yun‐Da Li, Somayeh H. Ahmad, Calvin K. Chan, Serena S. Hu, Harsh Wadhwa, James M. Mok, Javier Castro, Karl Bruckman
article en

Abstract

Study DesignBiomechanical.ObjectivesTo compare subaxial cervical stability with a dental composite-plate construct versus lateral mass screw-rod construct.Methods6 fresh-frozen human cadaveric cervical vertebrae (C4-C7) were prepared by stripping all soft tissues. Lateral mass screw fixation was performed bilaterally with standard freehand technique. Dental composite (Filtek) was applied to lamina before placement of a custom minifragment plate. Range of motion (ROM) and rotation to failure testing was performed using a robotic testing system (SimVITRO). Wilcoxon ranked sum test with Benjamini-Hochberg correction was used to compare results with significance set to p<0.05.ResultsThe screw-rod construct (5.1±4.0 deg) and composite-plate construct (4.5±3.2 deg) significantly decreased flexion-extension ROM relative to native state (8.1±1.7 deg, p<0.05). Only the composite-plate construct (2.7±1.9 deg) significantly decreased lateral bending ROM relative to native state (4.7±2.5 deg, p<0.05). Both the screw-rod construct (7.0±4.3 deg) and composite-plate construct (5.7±3.7 deg) significantly decreased axial rotation ROM relative to native state (9.9±5.2 deg, p<0.05). Composite-plate also decreased axial rotation ROM relative to screw-rod, while both constructs had comparable ROM in flexion-extension and lateral bending. Flexion to failure for the composite-plate construct was 7.1 ± 1.7 N-m. Mechanism of failure was the composite cracking off bone.ConclusionScrew-rod and composite-plate constructs significantly decrease ROM compared to the native state and are comparable in stiffness. Failure of composite-plate occurs with composite cracking off undamaged bone surface. A strategy utilizing composite fixation may offer a reasonable alternative to screws for subaxial stabilization.

Global Spine Journal
Stanford Medicine (US)
Good health and well-being
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon