A New Classification of High-Riding Vertebral Artery for Safe C2 Screw Placement

Abstract A New Classification of High-Riding Vertebral Artery for Safe C2 Screw Placement I.Abstract Background: The high-riding vertebral artery (HRVA) is the most common V3 segment variant and significantly increases the risk of C2 screw placement. However, existing classifications system lack direct integration with surgical planning. This study proposes a novel HRVA classification system based on parameters directly relevant to C2 isthmic screw fixation. Methods: We retrospectively analyzed 243 HRVA sides from 211 patients who underwent posterior atlantoaxial fusion between 2016 and 2025. Using standardized CTA measurements, we quantified the C2 isthmus width and the maximum intraosseous trajectory length for a 3.5 mm C2 isthmic screw. Based on these parameters and the screw length required for adequate purchase (9–14 mm), HRVA was classified into four subtypes (A、B、C、D). Inter-observer reliability was assessed using the Kappa test.Results: The distribution was: Type A (isthmus width ≥ 3.5 mm) in 18 (7.4%), Type B (width < 3.5 mm, length ≥ 14 mm) in 46 (19%), Type C (width < 3.5 mm, length 9–14 mm) in 178 (73%), and Type D (width < 3.5 mm, length < 9 mm) in 1 (0.4%). The CC combination was most common (53%) in bilateral cases. Inter-observer reliability was excellent for both measurements (κ = 0.895) and classification (κ = 0.827). Conclusions: This novel classification, based on C2 isthmus width and intraosseous screw trajectory length, provides a practical, surgeon-oriented tool for preoperative risk stratification and individualized screw placement strategy in patients with HRVA, potentially improving surgical decision-making. Further prospective multicenter studies are warranted to validate its clinical utility.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-17
DOI
https://doi.org/10.21203/rs.3.rs-11482397/v1
Primary Topic
Spinal Fractures and Fixation Techniques
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A New Classification of High-Riding Vertebral Artery for Safe C2 Screw Placement

Mingjun Xi, Xiaoxia Qu, Beixi Bao, Jian-hua Tao et al.
5 links
Research Square
Spinal Fractures and Fixation Techniques
preprint

A New Classification of High-Riding Vertebral Artery for Safe C2 Screw Placement

Mingjun Xi, Xiaoxia Qu, Beixi Bao, Jian-hua Tao, Xiaokang Cheng, Jiaguang Tang
preprint en

Abstract

Abstract A New Classification of High-Riding Vertebral Artery for Safe C2 Screw Placement I.Abstract Background: The high-riding vertebral artery (HRVA) is the most common V3 segment variant and significantly increases the risk of C2 screw placement. However, existing classifications system lack direct integration with surgical planning. This study proposes a novel HRVA classification system based on parameters directly relevant to C2 isthmic screw fixation. Methods: We retrospectively analyzed 243 HRVA sides from 211 patients who underwent posterior atlantoaxial fusion between 2016 and 2025. Using standardized CTA measurements, we quantified the C2 isthmus width and the maximum intraosseous trajectory length for a 3.5 mm C2 isthmic screw. Based on these parameters and the screw length required for adequate purchase (9–14 mm), HRVA was classified into four subtypes (A、B、C、D). Inter-observer reliability was assessed using the Kappa test.Results: The distribution was: Type A (isthmus width ≥ 3.5 mm) in 18 (7.4%), Type B (width < 3.5 mm, length ≥ 14 mm) in 46 (19%), Type C (width < 3.5 mm, length 9–14 mm) in 178 (73%), and Type D (width < 3.5 mm, length < 9 mm) in 1 (0.4%). The CC combination was most common (53%) in bilateral cases. Inter-observer reliability was excellent for both measurements (κ = 0.895) and classification (κ = 0.827). Conclusions: This novel classification, based on C2 isthmus width and intraosseous screw trajectory length, provides a practical, surgeon-oriented tool for preoperative risk stratification and individualized screw placement strategy in patients with HRVA, potentially improving surgical decision-making. Further prospective multicenter studies are warranted to validate its clinical utility.

Research Square
Beijing Tongren Hospital (CN), Capital Medical University (CN)
National Natural Science Foundation of China, Government of Jiangxi Province
Good health and well-being
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon