Multi-Response Evaluation of HA/YSZ Powder-Mixed Electrical Discharge Machining of Ti-6Al-4V: Surface Integrity with Preliminary Antibacterial Assessment

This study comparatively investigated the effects of hydroxyapatite (HA), yttria-stabilized zirconia (YSZ), and a 50:50 wt.% HA–YSZ mixture on the powder-mixed electrical discharge machining (PMEDM) of Ti-6Al-4V, focusing on machining performance, surface integrity, and preliminary antibacterial activity. The nanopowders were dispersed in deionized water at a fixed total concentration of 1.0 g/L. A three-factor, three-level full factorial design comprising 27 experimental conditions was employed, with peak current (18, 24, and 30 A), pulse-on time (100, 150, and 200 μs), and nanopowder type as the investigated factors. Surface roughness (Ra), recast layer thickness (RLT), material removal rate (MRR), and electrode wear rate (EWR) were evaluated. Main-effects analysis of variance (ANOVA) indicated that nanopowder type significantly affected Ra, peak current and pulse-on time significantly influenced MRR, and all three factors significantly affected EWR, whereas no statistically significant main effect was detected for RLT. Grey relational analysis (GRA) ranked Experiment 14 (HA, 30 A, 100 μs) highest among the investigated conditions (GRG = 0.7468), followed by Experiments 1 and 25 (YSZ; GRG = 0.7406 and 0.7390, respectively). These rankings represent relative performance within the unreplicated experimental design rather than a statistically validated optimum. The three highest-ranked conditions were further characterized using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) and subjected to preliminary antibacterial assessment against a non-reference clinical isolate of Staphylococcus aureus. The total inhibition-zone diameters were 21, 20, and 30 mm for Experiments 14, 1, and 25, respectively, including the 8-mm specimen diameter, while the untreated Ti-6Al-4V reference showed no observable inhibition zone. The antibacterial assessment involved single observations without independent biological replication or a powder-free EDM control. Overall, the findings demonstrate response-dependent effects of the investigated PMEDM conditions and preliminary antibacterial responses of selected machined surfaces. Further replicated and controlled investigations are required to establish the mechanisms of inhibition and evaluate their biomedical relevance.

Authors

Institutions

Publication Details

Journal
Engineering and Technology Journal
Published
2026-11-16
DOI
https://doi.org/10.30684/2412-0758.2433
Primary Topic
Advanced Machining and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multi-Response Evaluation of HA/YSZ Powder-Mixed Electrical Discharge Machining of Ti-6Al-4V: Surface Integrity with Preliminary Antibacterial Assessment

Waqass S. Khudhir, Ali Mundher Mustafa, Sara. J. Shawi
Engineering and Technology Journal
Advanced Machining and Optimization Techniques
article

Multi-Response Evaluation of HA/YSZ Powder-Mixed Electrical Discharge Machining of Ti-6Al-4V: Surface Integrity with Preliminary Antibacterial Assessment

Waqass S. Khudhir, Ali Mundher Mustafa, Sara. J. Shawi
article en

Abstract

This study comparatively investigated the effects of hydroxyapatite (HA), yttria-stabilized zirconia (YSZ), and a 50:50 wt.% HA–YSZ mixture on the powder-mixed electrical discharge machining (PMEDM) of Ti-6Al-4V, focusing on machining performance, surface integrity, and preliminary antibacterial activity. The nanopowders were dispersed in deionized water at a fixed total concentration of 1.0 g/L. A three-factor, three-level full factorial design comprising 27 experimental conditions was employed, with peak current (18, 24, and 30 A), pulse-on time (100, 150, and 200 μs), and nanopowder type as the investigated factors. Surface roughness (Ra), recast layer thickness (RLT), material removal rate (MRR), and electrode wear rate (EWR) were evaluated. Main-effects analysis of variance (ANOVA) indicated that nanopowder type significantly affected Ra, peak current and pulse-on time significantly influenced MRR, and all three factors significantly affected EWR, whereas no statistically significant main effect was detected for RLT. Grey relational analysis (GRA) ranked Experiment 14 (HA, 30 A, 100 μs) highest among the investigated conditions (GRG = 0.7468), followed by Experiments 1 and 25 (YSZ; GRG = 0.7406 and 0.7390, respectively). These rankings represent relative performance within the unreplicated experimental design rather than a statistically validated optimum. The three highest-ranked conditions were further characterized using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) and subjected to preliminary antibacterial assessment against a non-reference clinical isolate of Staphylococcus aureus. The total inhibition-zone diameters were 21, 20, and 30 mm for Experiments 14, 1, and 25, respectively, including the 8-mm specimen diameter, while the untreated Ti-6Al-4V reference showed no observable inhibition zone. The antibacterial assessment involved single observations without independent biological replication or a powder-free EDM control. Overall, the findings demonstrate response-dependent effects of the investigated PMEDM conditions and preliminary antibacterial responses of selected machined surfaces. Further replicated and controlled investigations are required to establish the mechanisms of inhibition and evaluate their biomedical relevance.

Engineering and Technology JournalVol. 44(12)
University of Technology - Iraq (IQ)
Advanced Machining and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon