Comparative Analysis of G+30 Building With and Without Outrigger System by Using ETABS Software

A tall building has to resist wind and earthquake forces in addition to the gravity loads, and as the height increases the lateral stiffness becomes the main design requirement. An outrigger system connects the lateral load resisting frame with the outer columns and helps in reducing the sway of the building without increasing the member sizes much. The location of the outrigger along the height has a direct effect on how well it works. This paper presents the seismic analysis of a G+30 reinforced concrete building, about 93 m high, with a plan of 36 m x 36 m. Six models are studied: a bare frame, outrigger at storey 10, outrigger at storey 20, and outriggers at storeys 5 and 15, 10 and 20, and 15 and 25. Response spectrum analysis is carried out in ETABS for Seismic Zone V. Storey displacement, base shear, time period, frequency, storey acceleration, storey drift, storey shear, torsion and bending moment are compared for all the models. The top displacement reduced by 8.2% to 21.6% and the top acceleration by 9.1% to 36.1% when outriggers were provided. The best performance was seen for the outriggers at storeys 15 and 25.

Authors

Institutions

Publication Details

Journal
International Journal for Research in Applied Science and Engineering Technology
Published
2026-11-17
DOI
https://doi.org/10.22214/ijraset.2026.85729
Primary Topic
Seismic and Structural Analysis of Tall Buildings
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative Analysis of G+30 Building With and Without Outrigger System by Using ETABS Software

Kimidi Karthik, B. Prudvi Rani
International Journal for Research in Applied Science and Engineering Technology
Seismic and Structural Analysis of Tall Buildings
article

Comparative Analysis of G+30 Building With and Without Outrigger System by Using ETABS Software

Kimidi Karthik, B. Prudvi Rani
article en

Abstract

A tall building has to resist wind and earthquake forces in addition to the gravity loads, and as the height increases the lateral stiffness becomes the main design requirement. An outrigger system connects the lateral load resisting frame with the outer columns and helps in reducing the sway of the building without increasing the member sizes much. The location of the outrigger along the height has a direct effect on how well it works. This paper presents the seismic analysis of a G+30 reinforced concrete building, about 93 m high, with a plan of 36 m x 36 m. Six models are studied: a bare frame, outrigger at storey 10, outrigger at storey 20, and outriggers at storeys 5 and 15, 10 and 20, and 15 and 25. Response spectrum analysis is carried out in ETABS for Seismic Zone V. Storey displacement, base shear, time period, frequency, storey acceleration, storey drift, storey shear, torsion and bending moment are compared for all the models. The top displacement reduced by 8.2% to 21.6% and the top acceleration by 9.1% to 36.1% when outriggers were provided. The best performance was seen for the outriggers at storeys 15 and 25.

International Journal for Research in Applied Science and Engineering TechnologyVol. 14(11)
Andhra University (IN)
Industry, innovation and infrastructure, Sustainable cities and communities
Seismic and Structural Analysis of Tall Buildings
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon