Temporal characteristics of the Licox brain tissue oxygenation probe and implications for the future: new strategies for advanced neuromonitoring
Abstract Background Neuromonitoring devices use correlation indices of patient physiology that may compare data with format differences between devices. Cerebrovascular autoregulation can be monitored using the Oxygen Reactivity Index (ORx), a correlation between partial pressure of brain tissue oxygenation (PbtO2) and cerebral perfusion pressure (CPP). We examined temporal characteristics of data from a PbtO2 probe used commonly in the neurological intensive care unit to monitor cerebrovascular autoregulation and applied these findings retrospectively to patient data to estimate their impact. Methods Partial pressure of oxygen (pO2) data were collected using a Licox PbtO2 probe (Integra Lifesciences, Princeton, NJ) and an Integra CMP monitor (Version 1). The probe was equilibrated to room air (pO2 = 159 mmHg at sea level), followed by an instantaneous change in ambient pO2 by immersion into a carbonated solution (~6 g CO2/liter; pO2 ~ 0 mmHg), followed by a return to room air. A complex curve was fitted to the experimental data and used to transform CPP data recorded previously from a patient over one week to the same temporal characteristics as the PbtO2 data. The raw and transformed CPP curves were then compared to the raw PbtO2 data. Results Licox probe data followed a quadratic transitioning to a long time-constant asymptotic exponential curve after the probe was moved from low pO2 to high pO2. Compared to raw CPP data, transformed patient CPP data during a period of impaired cerebrovascular oxygen reactivity exhibited a much stronger correlation with PbtO2. Conclusions We mitigated a significant temporal issue with PbtO2 data and dramatically improved correlations between CPP and PbtO2 during periods of impaired cerebrovascular oxygen reactivity. Our findings have profound implications for the calculation of ORx and may be applicable to other monitoring systems and data types to enhance the value of information routinely collected in clinical settings.
Authors
- Mark Krasberg (ORCID: https://orcid.org/0009-0007-7288-932X)
- Howard Yonas
- Adam Pelah
- John Fredieu
Institutions
- Cleveland Clinic (US)
- University of New Mexico Hospital (US)
- Cleveland Clinic Research (US)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-17
- DOI
- https://doi.org/10.21203/rs.3.rs-11579280/v1
- Primary Topic
- Traumatic Brain Injury and Neurovascular Disturbances
- Type
- preprint
Funders
- Henry M. Jackson Foundation