A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances

This study presents an adaptive RST polynomial control framework for nonideal DC–DC buck converters under line and load disturbances, explicitly accounting for pulse-width modulation (PWM) update delay. RST refers to a polynomial control structure comprising the R, S, and T polynomials. Conventional fixed-gain controllers are typically designed around a nominal operating point and may therefore lead to degraded voltage regulation, larger transient deviations, increased current stress, and reduced disturbance-rejection capability when converter dynamics vary due to load changes, input-voltage disturbances, parasitic losses, and digital implementation delays. Fixed-parameter model-based polynomial controllers may also fail to preserve the desired closed-loop dynamics when the effective converter parameters vary with the operating condition. To address these limitations, a nonideal averaged model is used to obtain an affine discrete-time input–output representation, and the effective PWM update delay is incorporated into the RST pole-placement design. The plant is identified online using a bias-augmented autoregressive with exogenous input (ARX) model with forgetting-factor recursive least squares (RLS), where the affine term separates constant operating-point and quasi-static mismatch effects from dynamic coefficients. The RST polynomials are recomputed online through a Diophantine equation, with an integral factor included for offset rejection and constant-reference tracking. The controller is experimentally evaluated on a buck converter prototype and compared with a fixed-gain proportional–integral (PI) controller under start-up, load-resistance transitions, and input-voltage transitions. In the start-up test, inductor-current overshoot is reduced from 62.5% to 12.5%, and start-up time decreases from 16.7ms to 1.6ms. For the 48V to 70V input-voltage transition, voltage overshoot decreases from 6.7V to 0.2V. The results show improved transient shaping, lower current stress, and faster recovery compared with the fixed-gain PI controller under line and load disturbances.

Authors

Institutions

Publication Details

Journal
Symmetry
Published
2026-11-17
DOI
https://doi.org/10.3390/sym18111925
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances

Fatih Evran
1 links
Symmetry
Advanced DC-DC Converters
article

A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances

Fatih Evran
article en

Abstract

This study presents an adaptive RST polynomial control framework for nonideal DC–DC buck converters under line and load disturbances, explicitly accounting for pulse-width modulation (PWM) update delay. RST refers to a polynomial control structure comprising the R, S, and T polynomials. Conventional fixed-gain controllers are typically designed around a nominal operating point and may therefore lead to degraded voltage regulation, larger transient deviations, increased current stress, and reduced disturbance-rejection capability when converter dynamics vary due to load changes, input-voltage disturbances, parasitic losses, and digital implementation delays. Fixed-parameter model-based polynomial controllers may also fail to preserve the desired closed-loop dynamics when the effective converter parameters vary with the operating condition. To address these limitations, a nonideal averaged model is used to obtain an affine discrete-time input–output representation, and the effective PWM update delay is incorporated into the RST pole-placement design. The plant is identified online using a bias-augmented autoregressive with exogenous input (ARX) model with forgetting-factor recursive least squares (RLS), where the affine term separates constant operating-point and quasi-static mismatch effects from dynamic coefficients. The RST polynomials are recomputed online through a Diophantine equation, with an integral factor included for offset rejection and constant-reference tracking. The controller is experimentally evaluated on a buck converter prototype and compared with a fixed-gain proportional–integral (PI) controller under start-up, load-resistance transitions, and input-voltage transitions. In the start-up test, inductor-current overshoot is reduced from 62.5% to 12.5%, and start-up time decreases from 16.7ms to 1.6ms. For the 48V to 70V input-voltage transition, voltage overshoot decreases from 6.7V to 0.2V. The results show improved transient shaping, lower current stress, and faster recovery compared with the fixed-gain PI controller under line and load disturbances.

SymmetryVol. 18(11)
Düzce Üniversitesi (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Industry, innovation and infrastructure
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon