Forecast-Error-Aware Dual-Time-Scale Hierarchical Energy Management for Sustainable Operation of PV Microgrids with Battery–Supercapacitor Hybrid Energy Storage

The increasing penetration of photovoltaic (PV) generation introduces substantial uncertainties into microgrid energy management due to deviations between forecasted and actual generation and load demand. Conventional single-time-scale scheduling may impose additional regulation demands on batteries, increasing energy throughput, power fluctuations, and associated degradation costs. To address these challenges, this paper proposes a forecast-error-aware dual-time-scale hierarchical energy management strategy for a grid-connected PV microgrid equipped with a battery–supercapacitor hybrid energy storage system. The upper layer performs hourly economic scheduling by considering grid electricity transactions and battery degradation costs, while the lower layer conducts corrective optimization at 5 min intervals using updated source-load forecasts. Through receding-horizon optimization, reference tracking, and battery power-variation regulation, corrective power is coordinated among the battery, supercapacitor, and utility grid while respecting their operating constraints. A 48 h benchmark with three comparative strategies is conducted under a 10% normalized root mean square error (NRMSE), with all cases terminating at 10% battery SOC. Compared with conventional battery-based hourly scheduling, the proposed strategy reduces the total operating cost, battery energy throughput, and the battery power fluctuation index by 4.34%, 16.69%, and 38.40%, respectively. An additional 96 h evaluation, with battery SOC restored to 50% at successive period boundaries, retains a 9.96% reduction in the power fluctuation index but yields a higher operating cost and battery throughput. Sensitivity analysis under 5–20% NRMSE further shows relatively stable battery power fluctuations and increased supercapacitor utilization with forecasting uncertainty. These findings demonstrate the potential benefits of forecast-aware hierarchical coordination while indicating that economic and battery utilization outcomes depend on the operating scenario, evaluation horizon, and terminal-energy policy.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-16
DOI
https://doi.org/10.3390/en19225516
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Forecast-Error-Aware Dual-Time-Scale Hierarchical Energy Management for Sustainable Operation of PV Microgrids with Battery–Supercapacitor Hybrid Energy Storage

Weiqi Zhang, He Li, Xiaowei Feng, Wei Zhou et al.
Energies
Microgrid Control and Optimization
article

Forecast-Error-Aware Dual-Time-Scale Hierarchical Energy Management for Sustainable Operation of PV Microgrids with Battery–Supercapacitor Hybrid Energy Storage

Weiqi Zhang, He Li, Xiaowei Feng, Wei Zhou, Wei Liang
article en

Abstract

The increasing penetration of photovoltaic (PV) generation introduces substantial uncertainties into microgrid energy management due to deviations between forecasted and actual generation and load demand. Conventional single-time-scale scheduling may impose additional regulation demands on batteries, increasing energy throughput, power fluctuations, and associated degradation costs. To address these challenges, this paper proposes a forecast-error-aware dual-time-scale hierarchical energy management strategy for a grid-connected PV microgrid equipped with a battery–supercapacitor hybrid energy storage system. The upper layer performs hourly economic scheduling by considering grid electricity transactions and battery degradation costs, while the lower layer conducts corrective optimization at 5 min intervals using updated source-load forecasts. Through receding-horizon optimization, reference tracking, and battery power-variation regulation, corrective power is coordinated among the battery, supercapacitor, and utility grid while respecting their operating constraints. A 48 h benchmark with three comparative strategies is conducted under a 10% normalized root mean square error (NRMSE), with all cases terminating at 10% battery SOC. Compared with conventional battery-based hourly scheduling, the proposed strategy reduces the total operating cost, battery energy throughput, and the battery power fluctuation index by 4.34%, 16.69%, and 38.40%, respectively. An additional 96 h evaluation, with battery SOC restored to 50% at successive period boundaries, retains a 9.96% reduction in the power fluctuation index but yields a higher operating cost and battery throughput. Sensitivity analysis under 5–20% NRMSE further shows relatively stable battery power fluctuations and increased supercapacitor utilization with forecasting uncertainty. These findings demonstrate the potential benefits of forecast-aware hierarchical coordination while indicating that economic and battery utilization outcomes depend on the operating scenario, evaluation horizon, and terminal-energy policy.

EnergiesVol. 19(22)
Harbin Institute of Technology (CN), Inner Mongolia Electric Power (China) (CN)
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon