A Simulation-Based Evaluation of an Intelligent Self-Cooling Personal Protective Equipment System for Firefighters in Zimbabwe

Firefighters operating in hot-climate regions such as Zimbabwe experience severe physiological heat strain because conventional multilayer turnout gear restricts evaporative and convective heat loss while providing no integrated thermoregulation.This paper presents the conceptual design, initial theoretical proof of concept, and preliminary economic analysis of an intelligent, self-cooling personal protective equipment (PPE)system architecture developed for resource-constrained fire services.Using a design-based engineering methodology informed by field observations, interviews, and a 40-respondent survey at two Bulawayo fire stations, a hybrid low-cost framework was selected from three candidates through a weighted decision matrix. The proposed architecture conceptually integrates an STM32L4 microcontroller, MAX30205 and MAX30102 physiological sensors, a five-state finite state machine controller, and a hybrid thermal management subsystem combining active micro-ventilation (~50 W convective, 5.2 L/s flow rate) with passive phase-change material (PCM) buffering (~30 W conductive heat flux), targeting a theoretical cooling capacity of approximately 80 W. Three-zone conjugate-heat-transfer computational fluid dynamics (CFD) modelling and transient MATLAB/Simulink thermal-electrical process simulations were used to evaluate the conceptual feasibility of the system layout in place of physical prototyping.Computational results demonstrate the theoretical viability of the forced-convection cooling pathway, showing a stable fan-driven pressure gradient and an analytical 4.8-minute (25.0%) extension in the baseline time required to reach the 39°C critical core-temperature threshold defined by NFPA 1584 (increasing from an uncooled baseline of 19.16 minutes to 23.95 minutes under a simulated 400 W metabolic load). Process modeling also suggests a theoretical cycle-averaged battery endurance exceeding eight hours. Preliminary economic modeling indicates a projected batch production cost of USD 260 per unit, with 43.8% of structural components sourceable regionally. These findings provide baseline computational performance estimates that establish the technical plausibility and architectural logic of a locally adapted,intelligent PPE concept prior to physical development

Authors

Institutions

Publication Details

Journal
International Journal of Latest Technology in Engineering Management & Applied Science
Published
2026-11-17
DOI
https://doi.org/10.51583/ijltemas.2026.151000119
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Simulation-Based Evaluation of an Intelligent Self-Cooling Personal Protective Equipment System for Firefighters in Zimbabwe

M. Ndebele, R. Rwaringesu, A. Janga
International Journal of Latest Technology in Engineering Management & Applied Science
Thermoregulation and physiological responses
article

A Simulation-Based Evaluation of an Intelligent Self-Cooling Personal Protective Equipment System for Firefighters in Zimbabwe

M. Ndebele, R. Rwaringesu, A. Janga
article en

Abstract

Firefighters operating in hot-climate regions such as Zimbabwe experience severe physiological heat strain because conventional multilayer turnout gear restricts evaporative and convective heat loss while providing no integrated thermoregulation.This paper presents the conceptual design, initial theoretical proof of concept, and preliminary economic analysis of an intelligent, self-cooling personal protective equipment (PPE)system architecture developed for resource-constrained fire services.Using a design-based engineering methodology informed by field observations, interviews, and a 40-respondent survey at two Bulawayo fire stations, a hybrid low-cost framework was selected from three candidates through a weighted decision matrix. The proposed architecture conceptually integrates an STM32L4 microcontroller, MAX30205 and MAX30102 physiological sensors, a five-state finite state machine controller, and a hybrid thermal management subsystem combining active micro-ventilation (~50 W convective, 5.2 L/s flow rate) with passive phase-change material (PCM) buffering (~30 W conductive heat flux), targeting a theoretical cooling capacity of approximately 80 W. Three-zone conjugate-heat-transfer computational fluid dynamics (CFD) modelling and transient MATLAB/Simulink thermal-electrical process simulations were used to evaluate the conceptual feasibility of the system layout in place of physical prototyping.Computational results demonstrate the theoretical viability of the forced-convection cooling pathway, showing a stable fan-driven pressure gradient and an analytical 4.8-minute (25.0%) extension in the baseline time required to reach the 39°C critical core-temperature threshold defined by NFPA 1584 (increasing from an uncooled baseline of 19.16 minutes to 23.95 minutes under a simulated 400 W metabolic load). Process modeling also suggests a theoretical cycle-averaged battery endurance exceeding eight hours. Preliminary economic modeling indicates a projected batch production cost of USD 260 per unit, with 43.8% of structural components sourceable regionally. These findings provide baseline computational performance estimates that establish the technical plausibility and architectural logic of a locally adapted,intelligent PPE concept prior to physical development

International Journal of Latest Technology in Engineering Management & Applied ScienceVol. 15(10)
Great Zimbabwe University (ZW), Chinhoyi University of Technology (ZW), University of Zimbabwe (ZW)
Good health and well-being
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon