Highly Superficial Flexible Coil Array for 1.5T MRI: Diagnostic Quality Evaluation Compared to Conventional Technology

OBJECTIVE: To assess the imaging performance, thermal behavior, and patient acceptance of a novel 3-channel flexible coil array for 1.5T MRI (64 MHz), compared to a conventional 16-channel flexible coil. METHODS: A lightweight array with three 60 mm copper loops and a compact 32×15 mm electronics board was developed, integrating tuning, matching, decoupling, RF filtering, and preamplification. Bench tests evaluated Q-factor ratio, SNR degradation under bending, phantom-based SNR, and thermal dissipation. Clinical evaluation involved hand imaging of 10 healthy volunteers (22.9 ± 0.3 years) using Cor-T1 and Ax-T2FS sequences in two positions (superman and supine). Image quality was rated by two radiologists across five tissue types using a 5-point Likert scale. Patient comfort and anxiety were assessed via post-scan questionnaires. RESULTS: In vitro tests showed a 1.6-fold SNR improvement for superficial regions (≤10 mm depth) and approximately 40% SNR loss under extreme bending, confirming robust decoupling and conformability. Radiologists reported significantly better image quality for Ax-T2FS with the flexible array, while Cor-T1 showed no significant difference. Patient comfort was markedly higher with the flexible array (85% vs. 45%), suggesting ergonomic advantages that may reduce motion artifacts. CONCLUSION: The proposed flexible 1.5T coil array enhances superficial SNR and patient comfort without compromising diagnostic quality. SIGNIFICANCE: High-density arrays of small coils can deliver clinical benefits at 1.5T, supporting their use for improved imaging in anatomically challenging regions.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Engineering
Published
2026-11-17
DOI
https://doi.org/10.1109/tbme.2026.3754547
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Highly Superficial Flexible Coil Array for 1.5T MRI: Diagnostic Quality Evaluation Compared to Conventional Technology

Antonio Martínez‐González, Juan Diego Sanchez-Heredia, Margarita Martínez-Fernández, José María García‐Santos et al.
IEEE Transactions on Biomedical Engineering
Advanced MRI Techniques and Applications
article

Highly Superficial Flexible Coil Array for 1.5T MRI: Diagnostic Quality Evaluation Compared to Conventional Technology

Antonio Martínez‐González, Juan Diego Sanchez-Heredia, Margarita Martínez-Fernández, José María García‐Santos, Almudena García-Gerónimo, Vicente Caruana Denia, Enrique Hernández-Zurita, Laura Pérez-Sánchez
article en

Abstract

OBJECTIVE: To assess the imaging performance, thermal behavior, and patient acceptance of a novel 3-channel flexible coil array for 1.5T MRI (64 MHz), compared to a conventional 16-channel flexible coil. METHODS: A lightweight array with three 60 mm copper loops and a compact 32×15 mm electronics board was developed, integrating tuning, matching, decoupling, RF filtering, and preamplification. Bench tests evaluated Q-factor ratio, SNR degradation under bending, phantom-based SNR, and thermal dissipation. Clinical evaluation involved hand imaging of 10 healthy volunteers (22.9 ± 0.3 years) using Cor-T1 and Ax-T2FS sequences in two positions (superman and supine). Image quality was rated by two radiologists across five tissue types using a 5-point Likert scale. Patient comfort and anxiety were assessed via post-scan questionnaires. RESULTS: In vitro tests showed a 1.6-fold SNR improvement for superficial regions (≤10 mm depth) and approximately 40% SNR loss under extreme bending, confirming robust decoupling and conformability. Radiologists reported significantly better image quality for Ax-T2FS with the flexible array, while Cor-T1 showed no significant difference. Patient comfort was markedly higher with the flexible array (85% vs. 45%), suggesting ergonomic advantages that may reduce motion artifacts. CONCLUSION: The proposed flexible 1.5T coil array enhances superficial SNR and patient comfort without compromising diagnostic quality. SIGNIFICANCE: High-density arrays of small coils can deliver clinical benefits at 1.5T, supporting their use for improved imaging in anatomically challenging regions.

IEEE Transactions on Biomedical EngineeringVol. PP
Universidad Politécnica de Cartagena (ES), Hospital General Universitario Morales Meseguer (ES)
Good health and well-being
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon