Neutral Manganese(II) Complex Scintillators With Sterically Locked Coordination Sites: A New Platform for High‐Performance X‐Ray Imaging

ABSTRACT Benefiting from flexible structural design and excellent water resistance, neutral manganese(II) complex‐based scintillators have attracted increasing attention in the field of X‑ray imaging. Nevertheless, compared with ionic manganese(II) halides, neutral systems generally suffer from low photoluminescence quantum yield (PLQY), which further leads to insufficient light yield (LY) and limited imaging resolution. To address these bottlenecks, this work presents a long‑range steric‑hindrance ligand modification strategy. By rendering one P═O coordination site of the bidentate phosphine ligand sterically locked, bulky bis‑ligand‑coordinated neutral monodentate manganese(II) complexes, (dCyXantPO) 2 MnBr 2 and (dCyXantPO) 2 MnCl 2 , were successfully synthesized. Owing to the distinctive coordination configuration, (dCyXantPO) 2 MnBr 2 crystals achieve a high PLQY of 95.3% and exhibit thermally activated luminescence behavior in the temperature range of 100–240 K. Meanwhile, the bulky steric organic ligand effectively improves the hydrophobicity of the emitters, enabling (dCyXantPO) 2 MnBr 2 crystals to retain stable luminescence for more than 15 days under water immersion. Under X‑ray irradiation, (dCyXantPO) 2 MnBr 2 crystals deliver a high LY of 30 600 photons MeV −1 with a low detection limit of 50.49 nGy s −1 . The (dCyXantPO) 2 MnBr 2 ‑doped PMMA scintillator film reaches a spatial resolution of 13.91 lp mm −1 , fully demonstrating the great potential for high‐performance X‑ray imaging.

Authors

Institutions

Publication Details

Journal
Laser & Photonics Review
Published
2026-11-16
DOI
https://doi.org/10.1002/lpor.72233
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Neutral Manganese(II) Complex Scintillators With Sterically Locked Coordination Sites: A New Platform for High‐Performance X‐Ray Imaging

Peng Tao, Qiang Zhao, Shujuan Liu, Xiaokang Zheng
Laser & Photonics Review
Radiation Detection and Scintillator Technologies
article

Neutral Manganese(II) Complex Scintillators With Sterically Locked Coordination Sites: A New Platform for High‐Performance X‐Ray Imaging

Peng Tao, Qiang Zhao, Shujuan Liu, Xiaokang Zheng
article en

Abstract

ABSTRACT Benefiting from flexible structural design and excellent water resistance, neutral manganese(II) complex‐based scintillators have attracted increasing attention in the field of X‑ray imaging. Nevertheless, compared with ionic manganese(II) halides, neutral systems generally suffer from low photoluminescence quantum yield (PLQY), which further leads to insufficient light yield (LY) and limited imaging resolution. To address these bottlenecks, this work presents a long‑range steric‑hindrance ligand modification strategy. By rendering one P═O coordination site of the bidentate phosphine ligand sterically locked, bulky bis‑ligand‑coordinated neutral monodentate manganese(II) complexes, (dCyXantPO) 2 MnBr 2 and (dCyXantPO) 2 MnCl 2 , were successfully synthesized. Owing to the distinctive coordination configuration, (dCyXantPO) 2 MnBr 2 crystals achieve a high PLQY of 95.3% and exhibit thermally activated luminescence behavior in the temperature range of 100–240 K. Meanwhile, the bulky steric organic ligand effectively improves the hydrophobicity of the emitters, enabling (dCyXantPO) 2 MnBr 2 crystals to retain stable luminescence for more than 15 days under water immersion. Under X‑ray irradiation, (dCyXantPO) 2 MnBr 2 crystals deliver a high LY of 30 600 photons MeV −1 with a low detection limit of 50.49 nGy s −1 . The (dCyXantPO) 2 MnBr 2 ‑doped PMMA scintillator film reaches a spatial resolution of 13.91 lp mm −1 , fully demonstrating the great potential for high‐performance X‑ray imaging.

Laser & Photonics Review
Hong Kong Polytechnic University (HK), Nanjing University of Information Science and Technology (CN), Nanjing University of Science and Technology (CN), Nanjing University of Posts and Telecommunications (CN)
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon