Real-time dosimetry in interventional radiology—comparing the operators’ radiation dose and associated factors for five types of transarterial embolization procedures

Objective This study aimed to record operators’ radiation doses during routine transarterial embolization using a real-time radiation dosimeter and to investigate the influencing factors of occupational radiation exposure. Materials and methods A total of 222 transarterial embolization procedures, including 133 transarterial chemoembolization (TACE), 35 bronchial artery embolization (BAE), 26 renal artery embolization (RAE), 15 uterine artery embolization (UAE), and 13 genicular artery embolization (GAE) procedures, were prospectively enrolled. Data related to patient characteristics, operator information, and radiation dose parameters were recorded. The kerma-area product ( P KA ) and effective dose (ED) were used to quantify patients’ radiation dose. The operator radiation dose equivalent, Hp(10), was recorded using a real-time dosimeter placed outside the lead apron at the left upper chest. The Mann–Whitney U test, the Kruskal–Wallis H test, and multivariate linear regression analysis were performed. Results In this investigation, 19 patients (9.79%) had an ED greater than 100 mSv. The GAE procedures were associated with significantly prolonged fluoroscopy time and higher radiation doses for first operators, whereas the UAE group yielded higher fluoroscopy P KA and air kerma ( K a,r). Both fluoroscopy time and the fluoroscopy P KA were correlated with the first operators’ radiation doses. The first operators received higher radiation doses than secondary operators during TACE, BAE, RAE, UAE, and GAE procedures. Multivariate regression demonstrated that the first operator’s radiation dose rate was associated with patient body mass index (BMI) ≥ 25 kg/m 2 ( p = 0.030), the operator’s experience ( p = 0.026), the operator’s height ( p = 0.011), the visual field size ( p = 0.007), and the type of interventional transarterial embolization procedure ( p < 0.050). Conclusion Operators’ radiation doses varied across different transarterial embolization procedures. Fluoroscopy time and P KA , the operator’s position, height, and experience, and the visual field size were related to the operators’ radiation dose.

Authors

Institutions

Publication Details

Journal
Frontiers in Public Health
Published
2026-11-17
DOI
https://doi.org/10.3389/fpubh.2026.1868748
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Real-time dosimetry in interventional radiology—comparing the operators’ radiation dose and associated factors for five types of transarterial embolization procedures

Yuxin Chen, Chaoyun Zhao, Ziyu Wang, Minglei Wang et al.
1 links
Frontiers in Public Health
Radiation Dose and Imaging
article

Real-time dosimetry in interventional radiology—comparing the operators’ radiation dose and associated factors for five types of transarterial embolization procedures

Yuxin Chen, Chaoyun Zhao, Ziyu Wang, Minglei Wang, Rong Lu, Yuanyuan Tong, Longyun Wu, Yong Chen, Xinrui Lv, Guanhua Yang
article en

Abstract

Objective This study aimed to record operators’ radiation doses during routine transarterial embolization using a real-time radiation dosimeter and to investigate the influencing factors of occupational radiation exposure. Materials and methods A total of 222 transarterial embolization procedures, including 133 transarterial chemoembolization (TACE), 35 bronchial artery embolization (BAE), 26 renal artery embolization (RAE), 15 uterine artery embolization (UAE), and 13 genicular artery embolization (GAE) procedures, were prospectively enrolled. Data related to patient characteristics, operator information, and radiation dose parameters were recorded. The kerma-area product ( P KA ) and effective dose (ED) were used to quantify patients’ radiation dose. The operator radiation dose equivalent, Hp(10), was recorded using a real-time dosimeter placed outside the lead apron at the left upper chest. The Mann–Whitney U test, the Kruskal–Wallis H test, and multivariate linear regression analysis were performed. Results In this investigation, 19 patients (9.79%) had an ED greater than 100 mSv. The GAE procedures were associated with significantly prolonged fluoroscopy time and higher radiation doses for first operators, whereas the UAE group yielded higher fluoroscopy P KA and air kerma ( K a,r). Both fluoroscopy time and the fluoroscopy P KA were correlated with the first operators’ radiation doses. The first operators received higher radiation doses than secondary operators during TACE, BAE, RAE, UAE, and GAE procedures. Multivariate regression demonstrated that the first operator’s radiation dose rate was associated with patient body mass index (BMI) ≥ 25 kg/m 2 ( p = 0.030), the operator’s experience ( p = 0.026), the operator’s height ( p = 0.011), the visual field size ( p = 0.007), and the type of interventional transarterial embolization procedure ( p < 0.050). Conclusion Operators’ radiation doses varied across different transarterial embolization procedures. Fluoroscopy time and P KA , the operator’s position, height, and experience, and the visual field size were related to the operators’ radiation dose.

Frontiers in Public HealthVol. 14
Capital Medical University (CN), Beijing Chao-Yang Hospital, Capital Medical University (CN), Ningxia Medical University (CN), Ningxia Medical University General Hospital (CN)
Good health and well-being
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon