External Manual Aortic Compression as a Temporizing Measure During Inter-Facility Transfer of a Woman With Life-Threatening Obstetric Hemorrhage in a Resource-Limited Setting: A Case Report From Ethiopia

Severe postpartum hemorrhage can be fatal when blood products, devices, and transfer are unavailable. External manual aortic compression (EMAC) may reduce distal blood flow temporarily. A 24-year-old woman at 37 weeks and 2 days presented after five hours of vaginal bleeding and developed shock following vaginal delivery, with blood loss exceeding 3,000 mL. Initial measures failed to control bleeding. Because the referring facility had neither blood products nor a non-pneumatic anti-shock garment, the attending gynecologist maintained EMAC for approximately 65 minutes during ambulance transfer. At the referral hospital, she received eight units of whole blood and three units of fresh frozen plasma and underwent B-Lynch uterine compression suturing. She developed acute kidney injury requiring three hemodialysis sessions. Renal function recovered, and she remained well through 12 months. This case illustrates EMAC as a temporary bridge to definitive treatment, not a substitute for urgent transfer, resuscitation, transfusion, or hemorrhage control.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-18
DOI
https://doi.org/10.21203/rs.3.rs-11381462/v1
Primary Topic
Maternal and fetal healthcare
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

External Manual Aortic Compression as a Temporizing Measure During Inter-Facility Transfer of a Woman With Life-Threatening Obstetric Hemorrhage in a Resource-Limited Setting: A Case Report From Ethiopia

Nigat Amsalu Addis, Fetene Seyoum Kebede, Kinfemicheal Tilahun Yigzaw, Moges Addis Fetene et al.
2 links
Research Square
Maternal and fetal healthcare
preprint

External Manual Aortic Compression as a Temporizing Measure During Inter-Facility Transfer of a Woman With Life-Threatening Obstetric Hemorrhage in a Resource-Limited Setting: A Case Report From Ethiopia

Nigat Amsalu Addis, Fetene Seyoum Kebede, Kinfemicheal Tilahun Yigzaw, Moges Addis Fetene, Melake Getahun Fikru
preprint en

Abstract

Severe postpartum hemorrhage can be fatal when blood products, devices, and transfer are unavailable. External manual aortic compression (EMAC) may reduce distal blood flow temporarily. A 24-year-old woman at 37 weeks and 2 days presented after five hours of vaginal bleeding and developed shock following vaginal delivery, with blood loss exceeding 3,000 mL. Initial measures failed to control bleeding. Because the referring facility had neither blood products nor a non-pneumatic anti-shock garment, the attending gynecologist maintained EMAC for approximately 65 minutes during ambulance transfer. At the referral hospital, she received eight units of whole blood and three units of fresh frozen plasma and underwent B-Lynch uterine compression suturing. She developed acute kidney injury requiring three hemodialysis sessions. Renal function recovered, and she remained well through 12 months. This case illustrates EMAC as a temporary bridge to definitive treatment, not a substitute for urgent transfer, resuscitation, transfusion, or hemorrhage control.

Research Square
Debre Berhan University (ET), Addis Ababa University (ET), University of Gondar (ET)
Good health and well-being
Maternal and fetal healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.