An Integrated LoRa Fog and Digital Twin Framework for Predictive Maintenance of Telecommunication Shelters

Telecommunication shelters depend on environmental control and backup power to protect network equipment, yet fixed-threshold monitoring often identifies faults only after conditions have deteriorated. This paper presents a simulation-based predictive-maintenance framework that combines LoRa telemetry, fog-level analytics, a synchronized digital twin, and a convolutional neural network–long short-term memory (CNN–LSTM) model. The simulated shelter produced multivariate temperature, humidity, power, cooling, battery, and grid-state telemetry at five-minute intervals over a nine-day horizon. Controlled scenarios represented cooling degradation and failure, door opening, load increase, and grid outage. A LoRa link model introduced packet loss and delay; fog processing smoothed signals, reconstructed missing timestamps, and generated local anomaly alerts. The digital twin tracked thermal, humidity, and power states, while a multi-task CNN–LSTM classified health states and estimated remaining useful life (RUL). Under the reported configuration, mean LoRa packet success was 86.3% and mean latency was 238 ms. Fog processing reduced temperature-signal variance by 41.6%, reconstructed 92.1% of missing timestamps, and achieved anomaly-detection precision, recall, and F1-score of 0.91, 0.87, and 0.89. Digital-twin tracking errors were 0.78 °C for temperature and 3.1% relative humidity for humidity. The CNN–LSTM achieved 0.94 accuracy and an RUL RMSE of 2.6 hours on the simulated evaluation data. Fog inference averaged 184 ms compared with 612 ms for the cloud-only comparison. These results indicate the potential of an integrated edge and digital-twin approach for shelter monitoring. Since the data and fault labels were simulation-generated, field validation remains necessary before operational use.

Authors

Institutions

Publication Details

Journal
Iconic Research and Engineering Journals
Published
2026-11-17
DOI
https://doi.org/10.64388/ire1725222
Primary Topic
IoT and Edge/Fog Computing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

An Integrated LoRa Fog and Digital Twin Framework for Predictive Maintenance of Telecommunication Shelters

Nwazor Nkolika, Gabriel Chibuoso Okpara
1 links
Iconic Research and Engineering Journals
IoT and Edge/Fog Computing
article

An Integrated LoRa Fog and Digital Twin Framework for Predictive Maintenance of Telecommunication Shelters

Nwazor Nkolika, Gabriel Chibuoso Okpara
article en

Abstract

Telecommunication shelters depend on environmental control and backup power to protect network equipment, yet fixed-threshold monitoring often identifies faults only after conditions have deteriorated. This paper presents a simulation-based predictive-maintenance framework that combines LoRa telemetry, fog-level analytics, a synchronized digital twin, and a convolutional neural network–long short-term memory (CNN–LSTM) model. The simulated shelter produced multivariate temperature, humidity, power, cooling, battery, and grid-state telemetry at five-minute intervals over a nine-day horizon. Controlled scenarios represented cooling degradation and failure, door opening, load increase, and grid outage. A LoRa link model introduced packet loss and delay; fog processing smoothed signals, reconstructed missing timestamps, and generated local anomaly alerts. The digital twin tracked thermal, humidity, and power states, while a multi-task CNN–LSTM classified health states and estimated remaining useful life (RUL). Under the reported configuration, mean LoRa packet success was 86.3% and mean latency was 238 ms. Fog processing reduced temperature-signal variance by 41.6%, reconstructed 92.1% of missing timestamps, and achieved anomaly-detection precision, recall, and F1-score of 0.91, 0.87, and 0.89. Digital-twin tracking errors were 0.78 °C for temperature and 3.1% relative humidity for humidity. The CNN–LSTM achieved 0.94 accuracy and an RUL RMSE of 2.6 hours on the simulated evaluation data. Fog inference averaged 184 ms compared with 612 ms for the cloud-only comparison. These results indicate the potential of an integrated edge and digital-twin approach for shelter monitoring. Since the data and fault labels were simulation-generated, field validation remains necessary before operational use.

Iconic Research and Engineering JournalsVol. 10(5)
University of Port Harcourt (NG)
Industry, innovation and infrastructure
IoT and Edge/Fog Computing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon