Accelerated Major Singlet Metabolite Mapping in Human Brain Using Nonwater/Fat‐Suppressed Ultrashort‐TR FID‐MRSI With FID‐Encoded IDEAL

Free-induction-decay MR spectroscopic imaging (FID-MRSI) with LCModel is a well-established, rapid brain metabolite mapping method. However, multislice whole brain coverage still entails substantial acquisition time. To enable water-referenced absolute mapping of the major brain singlets (total choline/creatine/N-acetylaspartate [tCho/tCr/tNAA]) with substantially reduced scan time, we developed nonwater/fat-suppressed ultrashort-TR FID-MRSI (uMRSI) combined with FID-encoded Iterative Decomposition with Echo Asymmetry and Least-squares estimation (IDEAL), a least-squares chemical shift separation framework using uniformly sampled FID points as temporal encodings at 3.0 T. The proposed uMRSI used only 128 FID points shortening TR to 80 ms (vs. 470 ms for conventional FID-MRSI [cMRSI]), yielding 10.58× shorter acquisition for water-referenced quantification. To reduce bias in major singlet quantification from nonnegligible spectral contributions, the FID-encoded IDEAL signal model also included glutamine-glutamate complex (Glx) and myo-inositol (mI) as singlet surrogates, in addition to tCho, tCr, and tNAA. Unsuppressed water and fat were suppressed using an orthogonality-based subspace-projection framework. Macromolecule (MM) basis functions were parameterized from metabolite-nulled data and incorporated into a two-stage FID-encoded IDEAL scheme that jointly estimated metabolite amplitudes, MM contributions, and local field offset. Phantom validation used healthy adult-range metabolite concentrations with added simulated MM; in vivo evaluation (n = 15) compared uMRSI + FID-encoded IDEAL with cMRSI + LCModel. The theoretical number of signal averages (NSA) approached the maximum for the five modeled metabolites. In phantom, major singlets showed low mean absolute percentage error (MAPE; 12.73% ± 3.76%) and Cramér-Rao lower bound (CRLB; 5.50% ± 1.80%), despite visually noticeable frequency-domain residuals. In vivo, tCho/tCr/tNAA maps showed moderate agreement versus cMRSI + LCModel (structural similarity index measure [SSIM] = 0.71/0.82/0.87; r = 0.67/0.69/0.62 [all p < 0.001]) with small Bland-Altman biases (-0.42/-1.20/-1.98 mM). The proposed uMRSI + FID-encoded IDEAL has potential for further accelerated, water-referenced absolute mapping of the major brain singlets at 3.0 T.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-11-17
DOI
https://doi.org/10.1002/nbm.70436
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Accelerated Major Singlet Metabolite Mapping in Human Brain Using Nonwater/Fat‐Suppressed Ultrashort‐TR FID‐MRSI With FID‐Encoded IDEAL

Ji‐hoon Kim, Hyeonjin Kim, Joon Hwan Jang
2 links
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

Accelerated Major Singlet Metabolite Mapping in Human Brain Using Nonwater/Fat‐Suppressed Ultrashort‐TR FID‐MRSI With FID‐Encoded IDEAL

Ji‐hoon Kim, Hyeonjin Kim, Joon Hwan Jang
article en

Abstract

Free-induction-decay MR spectroscopic imaging (FID-MRSI) with LCModel is a well-established, rapid brain metabolite mapping method. However, multislice whole brain coverage still entails substantial acquisition time. To enable water-referenced absolute mapping of the major brain singlets (total choline/creatine/N-acetylaspartate [tCho/tCr/tNAA]) with substantially reduced scan time, we developed nonwater/fat-suppressed ultrashort-TR FID-MRSI (uMRSI) combined with FID-encoded Iterative Decomposition with Echo Asymmetry and Least-squares estimation (IDEAL), a least-squares chemical shift separation framework using uniformly sampled FID points as temporal encodings at 3.0 T. The proposed uMRSI used only 128 FID points shortening TR to 80 ms (vs. 470 ms for conventional FID-MRSI [cMRSI]), yielding 10.58× shorter acquisition for water-referenced quantification. To reduce bias in major singlet quantification from nonnegligible spectral contributions, the FID-encoded IDEAL signal model also included glutamine-glutamate complex (Glx) and myo-inositol (mI) as singlet surrogates, in addition to tCho, tCr, and tNAA. Unsuppressed water and fat were suppressed using an orthogonality-based subspace-projection framework. Macromolecule (MM) basis functions were parameterized from metabolite-nulled data and incorporated into a two-stage FID-encoded IDEAL scheme that jointly estimated metabolite amplitudes, MM contributions, and local field offset. Phantom validation used healthy adult-range metabolite concentrations with added simulated MM; in vivo evaluation (n = 15) compared uMRSI + FID-encoded IDEAL with cMRSI + LCModel. The theoretical number of signal averages (NSA) approached the maximum for the five modeled metabolites. In phantom, major singlets showed low mean absolute percentage error (MAPE; 12.73% ± 3.76%) and Cramér-Rao lower bound (CRLB; 5.50% ± 1.80%), despite visually noticeable frequency-domain residuals. In vivo, tCho/tCr/tNAA maps showed moderate agreement versus cMRSI + LCModel (structural similarity index measure [SSIM] = 0.71/0.82/0.87; r = 0.67/0.69/0.62 [all p < 0.001]) with small Bland-Altman biases (-0.42/-1.20/-1.98 mM). The proposed uMRSI + FID-encoded IDEAL has potential for further accelerated, water-referenced absolute mapping of the major brain singlets at 3.0 T.

NMR in BiomedicineVol. 39(12)
Seoul National University (KR), Seoul National University of Education (KR), New Generation University College (ET), Seoul National University Hospital (KR), National Medical Center (KR)
National Research Foundation of Korea, Seoul National University Hospital
Good health and well-being
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon