Single‐Phase Inverter With Sensorless Observer Control and Multi‐Order Harmonic Compensation

ABSTRACT This paper proposes a sensorless control strategy for a single‐phase inverter based on a discrete‐time state observer. The proposed observer accurately reconstructs the AC‐side capacitor current, enabling capacitor current feedback without the need for a physical current sensor. To enhance power quality, a proportional–resonant (PR) controller with multiharmonic compensation is employed to suppress dominant low‐order harmonics and reduce total harmonic distortion (THD). Additionally, a one‐step‐ahead prediction scheme is adopted to mitigate digital control delays and enhance system stability. The proposed method is validated on a 2‐kW hardware prototype. Experimental results show that the output voltage THD is reduced from 11.82% to 5.18% under nonlinear load conditions, demonstrating significant improvement in output waveform quality and confirming the effectiveness of the approach.

Authors

Institutions

Publication Details

Journal
International Journal of Circuit Theory and Applications
Published
2026-11-17
DOI
https://doi.org/10.1002/cta.70710
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Single‐Phase Inverter With Sensorless Observer Control and Multi‐Order Harmonic Compensation

Zong-Zhen Yang
International Journal of Circuit Theory and Applications
Power Quality and Harmonics
article

Single‐Phase Inverter With Sensorless Observer Control and Multi‐Order Harmonic Compensation

Zong-Zhen Yang
article en

Abstract

ABSTRACT This paper proposes a sensorless control strategy for a single‐phase inverter based on a discrete‐time state observer. The proposed observer accurately reconstructs the AC‐side capacitor current, enabling capacitor current feedback without the need for a physical current sensor. To enhance power quality, a proportional–resonant (PR) controller with multiharmonic compensation is employed to suppress dominant low‐order harmonics and reduce total harmonic distortion (THD). Additionally, a one‐step‐ahead prediction scheme is adopted to mitigate digital control delays and enhance system stability. The proposed method is validated on a 2‐kW hardware prototype. Experimental results show that the output voltage THD is reduced from 11.82% to 5.18% under nonlinear load conditions, demonstrating significant improvement in output waveform quality and confirming the effectiveness of the approach.

International Journal of Circuit Theory and Applications
National Taiwan University of Science and Technology (TW)
Industry, innovation and infrastructure, Affordable and clean energy
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon