Accuracy of Cone-beam Computed Tomography in Determining Implant Length and Diameter: A Comparative Clinical Evaluation

Abstract Background: Accurate preoperative assessment of implant dimensions is a critical determinant of success in dental implant therapy. Precise estimation of implant length and diameter helps avoid complications such as cortical plate perforation, inferior alveolar nerve injury, and inadequate primary stability. Cone-beam computed tomography (CBCT) has become an important imaging modality in implant dentistry because it provides three-dimensional visualization with relatively low radiation exposure compared to conventional computed tomography. Aim: The study aimed to evaluate the accuracy of CBCT in determining implant length and diameter by comparing radiographic measurements with actual implant dimensions used during surgery. Study Design and Setting: This was a prospective, comparative clinical study conducted in a dental teaching hospital. Subjects and Methods: Patients requiring dental implant placement were included in the study. Preoperative CBCT scans were obtained, and measurements of proposed implant length and diameter were recorded using dedicated CBCT software. During implant placement, the actual implant length and diameter used were documented. Radiographic measurements obtained from CBCT were then compared with the clinical implant dimensions. Results: CBCT measurements showed a high degree of agreement with the actual implant length and diameter used during surgery. Minor discrepancies were observed, but these differences were within clinically acceptable limits. CBCT demonstrated high accuracy in preoperative assessment of implant dimensions. Conclusion: CBCT is a reliable and accurate imaging modality for determining implant length and diameter. Its use in preoperative planning can enhance surgical safety and improve the clinical outcomes in dental implant therapy.

Authors

Publication Details

Journal
Annals of African Medicine
Published
2026-11-16
DOI
https://doi.org/10.4103/aam.aam_658_26
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Accuracy of Cone-beam Computed Tomography in Determining Implant Length and Diameter: A Comparative Clinical Evaluation

Sravanthi Yadlapalli, Tripuraneni Rajesh Kumar
Annals of African Medicine
Dental Radiography and Imaging
article

Accuracy of Cone-beam Computed Tomography in Determining Implant Length and Diameter: A Comparative Clinical Evaluation

Sravanthi Yadlapalli, Tripuraneni Rajesh Kumar
article en

Abstract

Abstract Background: Accurate preoperative assessment of implant dimensions is a critical determinant of success in dental implant therapy. Precise estimation of implant length and diameter helps avoid complications such as cortical plate perforation, inferior alveolar nerve injury, and inadequate primary stability. Cone-beam computed tomography (CBCT) has become an important imaging modality in implant dentistry because it provides three-dimensional visualization with relatively low radiation exposure compared to conventional computed tomography. Aim: The study aimed to evaluate the accuracy of CBCT in determining implant length and diameter by comparing radiographic measurements with actual implant dimensions used during surgery. Study Design and Setting: This was a prospective, comparative clinical study conducted in a dental teaching hospital. Subjects and Methods: Patients requiring dental implant placement were included in the study. Preoperative CBCT scans were obtained, and measurements of proposed implant length and diameter were recorded using dedicated CBCT software. During implant placement, the actual implant length and diameter used were documented. Radiographic measurements obtained from CBCT were then compared with the clinical implant dimensions. Results: CBCT measurements showed a high degree of agreement with the actual implant length and diameter used during surgery. Minor discrepancies were observed, but these differences were within clinically acceptable limits. CBCT demonstrated high accuracy in preoperative assessment of implant dimensions. Conclusion: CBCT is a reliable and accurate imaging modality for determining implant length and diameter. Its use in preoperative planning can enhance surgical safety and improve the clinical outcomes in dental implant therapy.

Annals of African Medicine
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon