Supine Slow Vital Capacity as a Screening Test for Ultrasound-Defined Hemidiaphragm Dysfunction, with Exploratory Right-Versus-Left Comparisons

Background/Objectives: It is uncertain which widely available pulmonary function parameter best identifies hemidiaphragm dysfunction. We assessed how pulmonary function parameters agree with ultrasound-defined dysfunction and explored right-versus-left differences. Methods: We retrospectively studied 125 adults referred for suspected diaphragm dysfunction who underwent diaphragm ultrasound and pulmonary function testing, including seated and supine slow vital capacity (SVC) and maximal respiratory pressures. Dysfunction was defined as a diaphragm thickening fraction below 20%. Analyses included the area under the receiver-operating-characteristic curve (AUC), internal validation, fixed thresholds and intention-to-diagnose. Results: Forty-eight patients (38%) had dysfunction. Supine SVC had the highest AUC (0.837; 95% CI 0.761–0.904). Below a fixed threshold of 80% predicted, sensitivity was 98% (47/48), specificity 58% and the negative likelihood ratio 0.036 (95% CI 0.005–0.25). Validated sensitivity of the data-derived 78% cut-off depended on the method, because the Youden index was nearly flat: 95% (65–98%) after optimism correction, 71% by leave-one-out and 94% with a sensitivity-targeted rule. Supine SVC was unobtainable in 23% of encounters; counting these as positive, sensitivity was 98–99% and specificity 38–44%. Right-versus-left differences were inconsistent. Conclusions: In referred adults, a supine SVC above about 80% predicted may identify patients in whom ultrasound-defined dysfunction is unlikely, although a negative likelihood ratio ≤ 0.1 was not demonstrated with confidence; inability to lie flat should itself prompt ultrasound. External validation is required.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-17
DOI
https://doi.org/10.3390/diagnostics16223832
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Supine Slow Vital Capacity as a Screening Test for Ultrasound-Defined Hemidiaphragm Dysfunction, with Exploratory Right-Versus-Left Comparisons

Shigeki Fujitani, Patrick Koo, F. Dennis McCool, Mary B. Roberts et al.
3 links
Diagnostics
Ultrasound in Clinical Applications
article

Supine Slow Vital Capacity as a Screening Test for Ultrasound-Defined Hemidiaphragm Dysfunction, with Exploratory Right-Versus-Left Comparisons

Shigeki Fujitani, Patrick Koo, F. Dennis McCool, Mary B. Roberts, Taro Minami, Charles B. Eaton
article en

Abstract

Background/Objectives: It is uncertain which widely available pulmonary function parameter best identifies hemidiaphragm dysfunction. We assessed how pulmonary function parameters agree with ultrasound-defined dysfunction and explored right-versus-left differences. Methods: We retrospectively studied 125 adults referred for suspected diaphragm dysfunction who underwent diaphragm ultrasound and pulmonary function testing, including seated and supine slow vital capacity (SVC) and maximal respiratory pressures. Dysfunction was defined as a diaphragm thickening fraction below 20%. Analyses included the area under the receiver-operating-characteristic curve (AUC), internal validation, fixed thresholds and intention-to-diagnose. Results: Forty-eight patients (38%) had dysfunction. Supine SVC had the highest AUC (0.837; 95% CI 0.761–0.904). Below a fixed threshold of 80% predicted, sensitivity was 98% (47/48), specificity 58% and the negative likelihood ratio 0.036 (95% CI 0.005–0.25). Validated sensitivity of the data-derived 78% cut-off depended on the method, because the Youden index was nearly flat: 95% (65–98%) after optimism correction, 71% by leave-one-out and 94% with a sensitivity-targeted rule. Supine SVC was unobtainable in 23% of encounters; counting these as positive, sensitivity was 98–99% and specificity 38–44%. Right-versus-left differences were inconsistent. Conclusions: In referred adults, a supine SVC above about 80% predicted may identify patients in whom ultrasound-defined dysfunction is unlikely, although a negative likelihood ratio ≤ 0.1 was not demonstrated with confidence; inability to lie flat should itself prompt ultrasound. External validation is required.

DiagnosticsVol. 16(22)
University of Tennessee Health Science Center (US), St. Marianna University School of Medicine (JP), Brown University (US), Erlanger Health System (US), Kent Hospital (US)
Good health and well-being
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon