Systemic Haemodynamic and Neural-Autonomic Coupling During Common Peroneal Nerve Stimulation After Ischaemic Stroke: RETRAIN Phase 1 Study

Objective. Common peroneal nerve neuromuscular electrical stimulation (NMES), given after stroke to prevent venous thromboembolism, was associated with increased fNIRS haemoglobin oxygenation in the published primary analysis. We asked how far these optical responses reflect cardiac, vascular and neural-autonomic physiology, using EEG-fNIRS recordings. Approach. In RETRAIN Phase 1 (16 subacute patients, five NMES intensities), eight operationally distinct physiological families were each represented by one measure. Each was tested for stimulation versus baseline, first-block versus later-block differences and Optimal+1 versus Optimal, with exploratory question-wise Benjamini-Hochberg adjustment. Simulations, two open datasets with short channels and a compartment model set what the measures can mean. Sensitivity analyses excluded participants with a history of atrial fibrillation (AF). Main results. Optically inferred cardiac and respiratory predictors accounted for 29% excess predictability of slow global HbO variance relative to shifted controls. Blocks with larger heart rate rises showed larger global HbO and HbT rises but no HbR change (within-participant z +0.30, p = 0.012). EEG-haemodynamic (+0.034 excess coherence), brain-heart (Granger z +0.64) and cardiac-haemodynamic (+0.19) coupling exceeded surrogate nulls but did not track intensity. Mayer-band HbO power was lower in the first block (nominal), and higher at Optimal+1 than at Optimal (question-wise BH q = 0.002). In the 11 participants without AF, pulse amplitude fell by 12% in the first block (p < 0.001) and rose at Optimal+1 (p = 0.005). Pulse-amplitude contrasts differed by documented AF history (three AF-history participants with usable pulse data, between-group p = 0.003), and optical-pulse usability was 61% versus 93%. Significance. Optical haemodynamic signals co-varied with inferred cardiac and respiratory physiology. EEG-fNIRS coherence indicated cross-modal dependence that shared autonomic modulation and common amplitude envelopes can produce. Pulse-derived outcomes differed by documented AF history. Future studies should verify rhythm by simultaneous ECG and prespecify rhythm-aware analyses.

Authors

Publication Details

Journal
Preprints.org
Published
2026-11-17
DOI
https://doi.org/10.20944/preprints202611.1613.v1
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Systemic Haemodynamic and Neural-Autonomic Coupling During Common Peroneal Nerve Stimulation After Ischaemic Stroke: RETRAIN Phase 1 Study

Sandra Leason, Kausik Chatterjee, Anirban Dutta, Allam Harfoush
2 links
Preprints.org
Optical Imaging and Spectroscopy Techniques
preprint

Systemic Haemodynamic and Neural-Autonomic Coupling During Common Peroneal Nerve Stimulation After Ischaemic Stroke: RETRAIN Phase 1 Study

Sandra Leason, Kausik Chatterjee, Anirban Dutta, Allam Harfoush
preprint en

Abstract

Objective. Common peroneal nerve neuromuscular electrical stimulation (NMES), given after stroke to prevent venous thromboembolism, was associated with increased fNIRS haemoglobin oxygenation in the published primary analysis. We asked how far these optical responses reflect cardiac, vascular and neural-autonomic physiology, using EEG-fNIRS recordings. Approach. In RETRAIN Phase 1 (16 subacute patients, five NMES intensities), eight operationally distinct physiological families were each represented by one measure. Each was tested for stimulation versus baseline, first-block versus later-block differences and Optimal+1 versus Optimal, with exploratory question-wise Benjamini-Hochberg adjustment. Simulations, two open datasets with short channels and a compartment model set what the measures can mean. Sensitivity analyses excluded participants with a history of atrial fibrillation (AF). Main results. Optically inferred cardiac and respiratory predictors accounted for 29% excess predictability of slow global HbO variance relative to shifted controls. Blocks with larger heart rate rises showed larger global HbO and HbT rises but no HbR change (within-participant z +0.30, p = 0.012). EEG-haemodynamic (+0.034 excess coherence), brain-heart (Granger z +0.64) and cardiac-haemodynamic (+0.19) coupling exceeded surrogate nulls but did not track intensity. Mayer-band HbO power was lower in the first block (nominal), and higher at Optimal+1 than at Optimal (question-wise BH q = 0.002). In the 11 participants without AF, pulse amplitude fell by 12% in the first block (p < 0.001) and rose at Optimal+1 (p = 0.005). Pulse-amplitude contrasts differed by documented AF history (three AF-history participants with usable pulse data, between-group p = 0.003), and optical-pulse usability was 61% versus 93%. Significance. Optical haemodynamic signals co-varied with inferred cardiac and respiratory physiology. EEG-fNIRS coherence indicated cross-modal dependence that shared autonomic modulation and common amplitude envelopes can produce. Pulse-derived outcomes differed by documented AF history. Future studies should verify rhythm by simultaneous ECG and prespecify rhythm-aware analyses.

Preprints.org
Good health and well-being
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon