Uncovering Spatial Variations and Local Controls of River Cooling Effects Across Multiple Segment Scales in Wuhan, China

Urban rivers serve as vital cold sources for mitigating the urban thermal environment. Also, analysis units that are too large may obscure fine-scale local features, thereby impeding the precise identification of the core drivers governing waterfront spatial layouts. Yet how the scale of the river segment affects the identification of cooling effects and their driving factors remains rarely explored. Taking the Yangtze and Han Rivers in Wuhan as case studies, this research utilized Landsat remote sensing data to retrieve land surface temperature and quantified the River Cooling Intensity (RCI) and River Cooling Distance (RCD) across multi-scale river segments. We found that average river cooling intensity was 6.94 °C, with a mean cooling distance of 221.83 m and a maximum cooling distance of 856.19 m. Significant heterogeneity exists based on river type and location (urban vs. rural): the Han River segments exhibited higher average cooling intensity than the Yangtze, and urban segments showed significantly higher cooling intensity and distance compared to rural segments. XGBoost models for both RCI and RCD demonstrated highest explanatory power within the 250 m segment scale based on statistical analysis within the cooling boundary; however, as the segment range expanded to 2000 m, the explanatory capacity of both metrics declined. At the 250 m near-shore scale, the 3D morphology of riparian buildings and road density were mechanically linked to cooling effect, while at larger scales, the cool air from the river relied more on regional wind conditions than on the building morphology. Waterfront planning should adopt a tiered management framework to strengthen ventilation corridors. The research provides a theoretical basis for the refined assessment of urban river cooling effects and the optimization of the thermal environment in waterfront spaces.

Authors

Institutions

Publication Details

Journal
Land
Published
2026-11-17
DOI
https://doi.org/10.3390/land15112198
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Uncovering Spatial Variations and Local Controls of River Cooling Effects Across Multiple Segment Scales in Wuhan, China

Wenxiao Jia, Yiting Yun, Zhiyu Xu, Maizhe Wang et al.
3 links
Land
Urban Heat Island Mitigation
article

Uncovering Spatial Variations and Local Controls of River Cooling Effects Across Multiple Segment Scales in Wuhan, China

Wenxiao Jia, Yiting Yun, Zhiyu Xu, Maizhe Wang, Junling He, Yu Fan, Xinyuan Zhang, Ningxing Tian
article en

Abstract

Urban rivers serve as vital cold sources for mitigating the urban thermal environment. Also, analysis units that are too large may obscure fine-scale local features, thereby impeding the precise identification of the core drivers governing waterfront spatial layouts. Yet how the scale of the river segment affects the identification of cooling effects and their driving factors remains rarely explored. Taking the Yangtze and Han Rivers in Wuhan as case studies, this research utilized Landsat remote sensing data to retrieve land surface temperature and quantified the River Cooling Intensity (RCI) and River Cooling Distance (RCD) across multi-scale river segments. We found that average river cooling intensity was 6.94 °C, with a mean cooling distance of 221.83 m and a maximum cooling distance of 856.19 m. Significant heterogeneity exists based on river type and location (urban vs. rural): the Han River segments exhibited higher average cooling intensity than the Yangtze, and urban segments showed significantly higher cooling intensity and distance compared to rural segments. XGBoost models for both RCI and RCD demonstrated highest explanatory power within the 250 m segment scale based on statistical analysis within the cooling boundary; however, as the segment range expanded to 2000 m, the explanatory capacity of both metrics declined. At the 250 m near-shore scale, the 3D morphology of riparian buildings and road density were mechanically linked to cooling effect, while at larger scales, the cool air from the river relied more on regional wind conditions than on the building morphology. Waterfront planning should adopt a tiered management framework to strengthen ventilation corridors. The research provides a theoretical basis for the refined assessment of urban river cooling effects and the optimization of the thermal environment in waterfront spaces.

LandVol. 15(11)
Northwest A&F University (CN)
National Natural Science Foundation of China
Sustainable cities and communities, Clean water and sanitation, Climate action
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon