Signed Voltage Sensitivity and Trip-Aware Positive-Neighbour Control for Photovoltaic Hosting Capacity in a Four-Wire Rural Low-Voltage Network

Photovoltaic hosting capacity in low-voltage (LV) networks is usually assessed with balanced or three-wire models, although much of European rural distribution is four-wire with predominantly single-phase connections, where the neutral couples the phases and the voltage response to an injection depends on the phase of the injecting unit. This paper derives that dependence in closed form and builds a coordinated curtailment scheme on it. The test system is a 250 kVA rural substation in north-eastern Romania with 213 supply points, 95.3% of them single-phase, and 53 prosumers, whose feeder, pole and phase are taken from operator records. A four-wire power flow including the EN 50549-1 trip and reconnection sequence compares six inverter strategies with a proposed Trip-Aware Positive-Neighbour Control (PNC), in which the operator releases a per-inverter power ceiling at each averaging window and tightens it only on units with positive voltage sensitivity. The critical-node sensitivity is +3.294 V/kW on the injecting phase and negative on the other two, so only 35 of the 53 units can relieve it, and its sign depends on the power factor. Reactive absorption drives the non-generating phases to 202.0 V at midday. PNC and a local P(U) droop both reach 500 kWp, twice the transformer rating, but PNC curtails 23% less energy and keeps a Jain fairness index of 0.930 against 0.850. Prosumer phase allocation alone is worth 44% of the curtailed energy.

Authors

Publication Details

Journal
Preprints.org
Published
2026-11-16
DOI
https://doi.org/10.20944/preprints202611.1561.v1
Primary Topic
Optimal Power Flow Distribution
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Signed Voltage Sensitivity and Trip-Aware Positive-Neighbour Control for Photovoltaic Hosting Capacity in a Four-Wire Rural Low-Voltage Network

Ion Triștiu, Bogdan-Constantin Neagu, Gheorghe Grigoraş, Costica Adi Nazareanu et al.
Preprints.org
Optimal Power Flow Distribution
preprint

Signed Voltage Sensitivity and Trip-Aware Positive-Neighbour Control for Photovoltaic Hosting Capacity in a Four-Wire Rural Low-Voltage Network

Ion Triștiu, Bogdan-Constantin Neagu, Gheorghe Grigoraş, Costica Adi Nazareanu, Razvan-Constantin Beniuga
preprint en

Abstract

Photovoltaic hosting capacity in low-voltage (LV) networks is usually assessed with balanced or three-wire models, although much of European rural distribution is four-wire with predominantly single-phase connections, where the neutral couples the phases and the voltage response to an injection depends on the phase of the injecting unit. This paper derives that dependence in closed form and builds a coordinated curtailment scheme on it. The test system is a 250 kVA rural substation in north-eastern Romania with 213 supply points, 95.3% of them single-phase, and 53 prosumers, whose feeder, pole and phase are taken from operator records. A four-wire power flow including the EN 50549-1 trip and reconnection sequence compares six inverter strategies with a proposed Trip-Aware Positive-Neighbour Control (PNC), in which the operator releases a per-inverter power ceiling at each averaging window and tightens it only on units with positive voltage sensitivity. The critical-node sensitivity is +3.294 V/kW on the injecting phase and negative on the other two, so only 35 of the 53 units can relieve it, and its sign depends on the power factor. Reactive absorption drives the non-generating phases to 202.0 V at midday. PNC and a local P(U) droop both reach 500 kWp, twice the transformer rating, but PNC curtails 23% less energy and keeps a Jain fairness index of 0.930 against 0.850. Prosumer phase allocation alone is worth 44% of the curtailed energy.

Preprints.org
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon