A Natural Perturbation Reveals Dynamic Source Attribution of PM2.5-Associated PFAS between Outdoor Atmosphere and Indoor Environments
Abstract Distinguishing outdoor atmospheric inputs from indoor sources is essential for understanding the environmental cycling of PM2.5-associated per- and polyfluoroalkyl substances (PFAS). We used a wildfire smoke episode as a natural perturbation to distinguish the relative contributions of outdoor atmospheric inputs and indoor sources to PM2.5-associated PFAS. Target ionic PFAS were measured simultaneously in indoor and outdoor PM2.5 and indoor dust from ten residences in Calgary, Canada, under normal and wildfire-affected conditions. Positive matrix factorization (PMF) was applied to identify source-related factors, with factor interpretation constrained by independent evidence from indoor–outdoor concentration gradients, correlation analyses, and compositional similarities. Despite substantial increases in PM2.5 loading during the wildfire period, total PM2.5-associated PFAS concentrations decreased by 80.6% indoors and 92.5% outdoors relative to normal conditions, revealing a pronounced decoupling between PM2.5 mass and associated PFAS. PMF identified two indoor source signatures: a legacy PFAS-related factor consistent with the historical use of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA), and a perfluoroalkyl carboxylic acid (PFCA)-rich factor potentially associated with more contemporary PFAS use, including alternative PFAS products. Under normal conditions, outdoor-related factors contributed 47.6% of indoor PM2.5-associated PFAS. During the wildfire period, this contribution decreased to 26.2%, while both indoor source signatures remained evident, suggesting continued indoor PFAS inputs, potentially including uptake of indoor-derived PFAS by infiltrating particles with relatively low PFAS concentrations. Overall, these findings demonstrate that transient atmospheric perturbations can facilitate the differentiation of indoor and outdoor source contributions to particle-associated contaminants. They also indicate that indoor air quality during wildfire events is jointly influenced by infiltrating smoke, persistent indoor contaminant sources, and their potential interactions with infiltrating particles.
Authors
- Yulong Ma (ORCID: https://orcid.org/0000-0002-6302-3168)
- Ke Du (ORCID: https://orcid.org/0000-0002-8251-2928)
- Xiong Ying (ORCID: https://orcid.org/0000-0002-4285-1853)
- Junqi Li
Institutions
- Jinan University (CN)
- University of Calgary (CA)
- University of Birmingham (GB)
Publication Details
- Journal
- ACS ES&T Air
- Published
- 2026-11-17
- DOI
- https://doi.org/10.1021/acsestair.6c00341
- Primary Topic
- Per- and polyfluoroalkyl substances research
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Natural Sciences and Engineering Research Council of Canada