A Natural Perturbation Reveals Dynamic Source Attribution of PM2.5-Associated PFAS between Outdoor Atmosphere and Indoor Environments

Abstract Distinguishing outdoor atmospheric inputs from indoor sources is essential for understanding the environmental cycling of PM2.5-associated per- and polyfluoroalkyl substances (PFAS). We used a wildfire smoke episode as a natural perturbation to distinguish the relative contributions of outdoor atmospheric inputs and indoor sources to PM2.5-associated PFAS. Target ionic PFAS were measured simultaneously in indoor and outdoor PM2.5 and indoor dust from ten residences in Calgary, Canada, under normal and wildfire-affected conditions. Positive matrix factorization (PMF) was applied to identify source-related factors, with factor interpretation constrained by independent evidence from indoor–outdoor concentration gradients, correlation analyses, and compositional similarities. Despite substantial increases in PM2.5 loading during the wildfire period, total PM2.5-associated PFAS concentrations decreased by 80.6% indoors and 92.5% outdoors relative to normal conditions, revealing a pronounced decoupling between PM2.5 mass and associated PFAS. PMF identified two indoor source signatures: a legacy PFAS-related factor consistent with the historical use of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA), and a perfluoroalkyl carboxylic acid (PFCA)-rich factor potentially associated with more contemporary PFAS use, including alternative PFAS products. Under normal conditions, outdoor-related factors contributed 47.6% of indoor PM2.5-associated PFAS. During the wildfire period, this contribution decreased to 26.2%, while both indoor source signatures remained evident, suggesting continued indoor PFAS inputs, potentially including uptake of indoor-derived PFAS by infiltrating particles with relatively low PFAS concentrations. Overall, these findings demonstrate that transient atmospheric perturbations can facilitate the differentiation of indoor and outdoor source contributions to particle-associated contaminants. They also indicate that indoor air quality during wildfire events is jointly influenced by infiltrating smoke, persistent indoor contaminant sources, and their potential interactions with infiltrating particles.

Authors

Institutions

Publication Details

Journal
ACS ES&T Air
Published
2026-11-17
DOI
https://doi.org/10.1021/acsestair.6c00341
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Natural Perturbation Reveals Dynamic Source Attribution of PM2.5-Associated PFAS between Outdoor Atmosphere and Indoor Environments

Yulong Ma, Ke Du, Xiong Ying, Junqi Li
6 links
ACS ES&T Air
Per- and polyfluoroalkyl substances research
article

A Natural Perturbation Reveals Dynamic Source Attribution of PM2.5-Associated PFAS between Outdoor Atmosphere and Indoor Environments

Yulong Ma, Ke Du, Xiong Ying, Junqi Li
article en

Abstract

Abstract Distinguishing outdoor atmospheric inputs from indoor sources is essential for understanding the environmental cycling of PM2.5-associated per- and polyfluoroalkyl substances (PFAS). We used a wildfire smoke episode as a natural perturbation to distinguish the relative contributions of outdoor atmospheric inputs and indoor sources to PM2.5-associated PFAS. Target ionic PFAS were measured simultaneously in indoor and outdoor PM2.5 and indoor dust from ten residences in Calgary, Canada, under normal and wildfire-affected conditions. Positive matrix factorization (PMF) was applied to identify source-related factors, with factor interpretation constrained by independent evidence from indoor–outdoor concentration gradients, correlation analyses, and compositional similarities. Despite substantial increases in PM2.5 loading during the wildfire period, total PM2.5-associated PFAS concentrations decreased by 80.6% indoors and 92.5% outdoors relative to normal conditions, revealing a pronounced decoupling between PM2.5 mass and associated PFAS. PMF identified two indoor source signatures: a legacy PFAS-related factor consistent with the historical use of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA), and a perfluoroalkyl carboxylic acid (PFCA)-rich factor potentially associated with more contemporary PFAS use, including alternative PFAS products. Under normal conditions, outdoor-related factors contributed 47.6% of indoor PM2.5-associated PFAS. During the wildfire period, this contribution decreased to 26.2%, while both indoor source signatures remained evident, suggesting continued indoor PFAS inputs, potentially including uptake of indoor-derived PFAS by infiltrating particles with relatively low PFAS concentrations. Overall, these findings demonstrate that transient atmospheric perturbations can facilitate the differentiation of indoor and outdoor source contributions to particle-associated contaminants. They also indicate that indoor air quality during wildfire events is jointly influenced by infiltrating smoke, persistent indoor contaminant sources, and their potential interactions with infiltrating particles.

ACS ES&T Air
Jinan University (CN), University of Calgary (CA), University of Birmingham (GB)
Natural Sciences and Engineering Research Council of Canada
Good health and well-being
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon