Cyanoacrylate-Based Skin Adhesives and Incisional Complications in Panniculectomy and Abdominoplasty: A Retrospective Cohort Study

BACKGROUND: Comparative data on dressing selection after abdominal contouring, where closures bear high tension, remain limited. This study evaluated the association between dressing type and postoperative complications following abdominoplasty and panniculectomy. METHODS: Single-institution retrospective cohort study of patients undergoing abdominoplasty or panniculectomy. Dressings were silk fibroin mesh (SFM), Steri-Strips (STE), Aquacel (AQU), and cyanoacrylate adhesives (CYA); the CYA arm comprised Histoacryl (n=43), Dermabond (n=11), and Dermabond Prineo (n=10), analyzed both pooled and separately. Sensitivity analyses excluded fleur-de-lis incisions, restricted CYA to liquid formulations, and restricted to surgeons using both dressings. RESULTS: Of 125 patients, 64 received CYA, 39 SFM, 14 AQU, and 8 STE. Mean age was 47.4 years; mean BMI 33.4 kg/m2. Groups differed at baseline in ASA class, mesh use, and incision pattern, and in resection weight among the 72 patients with recorded values; fleur-de-lis incisions occurred only in CYA (n=7) and STE (n=2). Total complications were lower with SFM than CYA (15.4% vs 50.0%, p<0.001; aOR 0.17, 95% CI 0.06-0.45), an association that persisted across every sensitivity analysis, including fleur-de-lis exclusion (aOR 0.22, 95% CI 0.07-0.60, p=0.004) and separate analysis of each CYA product. Wound dehiscence and skin reaction were also lower with SFM, but these associations were not robust: with fleur-de-lis cases excluded, dehiscence (p=0.114) and skin reaction (p=0.137) were nonsignificant. CONCLUSIONS: CYA adhesives were associated with a higher overall incisional complication rate than SFM. Findings for individual complications were not robust and are reported as exploratory. These data support prospective evaluation of dressing selection.

Authors

Institutions

Publication Details

Journal
Plastic & Reconstructive Surgery
Published
2026-11-17
DOI
https://doi.org/10.1097/prs.0000000000013619
Primary Topic
Surgical Sutures and Adhesives
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Cyanoacrylate-Based Skin Adhesives and Incisional Complications in Panniculectomy and Abdominoplasty: A Retrospective Cohort Study

Gedge D. Rosson, Thomas Ren, Steven L. Zeng, Damon S. Cooney et al.
Plastic & Reconstructive Surgery
Surgical Sutures and Adhesives
article

Cyanoacrylate-Based Skin Adhesives and Incisional Complications in Panniculectomy and Abdominoplasty: A Retrospective Cohort Study

Gedge D. Rosson, Thomas Ren, Steven L. Zeng, Damon S. Cooney, Charbel G. Saad, Fares Lebbos, Ricardo Rodriguez-Colon
article en

Abstract

BACKGROUND: Comparative data on dressing selection after abdominal contouring, where closures bear high tension, remain limited. This study evaluated the association between dressing type and postoperative complications following abdominoplasty and panniculectomy. METHODS: Single-institution retrospective cohort study of patients undergoing abdominoplasty or panniculectomy. Dressings were silk fibroin mesh (SFM), Steri-Strips (STE), Aquacel (AQU), and cyanoacrylate adhesives (CYA); the CYA arm comprised Histoacryl (n=43), Dermabond (n=11), and Dermabond Prineo (n=10), analyzed both pooled and separately. Sensitivity analyses excluded fleur-de-lis incisions, restricted CYA to liquid formulations, and restricted to surgeons using both dressings. RESULTS: Of 125 patients, 64 received CYA, 39 SFM, 14 AQU, and 8 STE. Mean age was 47.4 years; mean BMI 33.4 kg/m2. Groups differed at baseline in ASA class, mesh use, and incision pattern, and in resection weight among the 72 patients with recorded values; fleur-de-lis incisions occurred only in CYA (n=7) and STE (n=2). Total complications were lower with SFM than CYA (15.4% vs 50.0%, p<0.001; aOR 0.17, 95% CI 0.06-0.45), an association that persisted across every sensitivity analysis, including fleur-de-lis exclusion (aOR 0.22, 95% CI 0.07-0.60, p=0.004) and separate analysis of each CYA product. Wound dehiscence and skin reaction were also lower with SFM, but these associations were not robust: with fleur-de-lis cases excluded, dehiscence (p=0.114) and skin reaction (p=0.137) were nonsignificant. CONCLUSIONS: CYA adhesives were associated with a higher overall incisional complication rate than SFM. Findings for individual complications were not robust and are reported as exploratory. These data support prospective evaluation of dressing selection.

Plastic & Reconstructive Surgery
Johns Hopkins University (US), Johns Hopkins Medicine (US)
Good health and well-being
Surgical Sutures and Adhesives
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon