Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport

Abstract The combined effect of geometric obstruction and auxiliary inlet on sensor response time for a microfluidics-integrated biosensor has been numerically investigated in this study. The flow behavior and mass transfer of an analyte have been modeled using incompressible Navier–Stokes equations coupled with convection–diffusion and Langmuir adsorption kinetics equations for comparable time scales of diffusion and surface reaction. Introduction of a block increases the analyte velocity near the sensor surface with subsequent reduction in diffusion boundary layer thickness, thereby ameliorating the sensor response time. Insertion of an auxiliary inlet diminishes the sensor response time to a greater extent by confining a thin layer of analyte above the sensor surface. A systematic parametric study is conducted to evaluate the blended effects of block height, block position, block width, auxiliary inlet position, and auxiliary inlet velocity on sensor performance. Taguchi-based optimization techniques employing an L27 orthogonal array alongside signal-to-noise ratio analysis and analysis of variance have been utilized for identification of optimal parameter combinations. The results indicate that the auxiliary inlet velocity is the most influential parameter with a contribution of 65.8% toward the decrement in sensor response time. The findings demonstrate that the combination of block-induced flow-field modifications and auxiliary-inlet-mediated flow confinement effect significantly augments analyte transport to the sensor surface, thereby decreasing the sensor response time by approximately 92% in comparison to the scenario devoid of a block and auxiliary inlet. This study provides valuable insights for the design and optimization of point-of-care microfluidic devices with reduced detection time.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-11-17
DOI
https://doi.org/10.1021/acsomega.6c12419
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport

Somnath Santra, Arnab Guha, Parikshit Sahatiya, Sayan Das et al.
ACS Omega
Microfluidic and Capillary Electrophoresis Applications
article

Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport

Somnath Santra, Arnab Guha, Parikshit Sahatiya, Sayan Das, N Muralikrishna
article en

Abstract

Abstract The combined effect of geometric obstruction and auxiliary inlet on sensor response time for a microfluidics-integrated biosensor has been numerically investigated in this study. The flow behavior and mass transfer of an analyte have been modeled using incompressible Navier–Stokes equations coupled with convection–diffusion and Langmuir adsorption kinetics equations for comparable time scales of diffusion and surface reaction. Introduction of a block increases the analyte velocity near the sensor surface with subsequent reduction in diffusion boundary layer thickness, thereby ameliorating the sensor response time. Insertion of an auxiliary inlet diminishes the sensor response time to a greater extent by confining a thin layer of analyte above the sensor surface. A systematic parametric study is conducted to evaluate the blended effects of block height, block position, block width, auxiliary inlet position, and auxiliary inlet velocity on sensor performance. Taguchi-based optimization techniques employing an L27 orthogonal array alongside signal-to-noise ratio analysis and analysis of variance have been utilized for identification of optimal parameter combinations. The results indicate that the auxiliary inlet velocity is the most influential parameter with a contribution of 65.8% toward the decrement in sensor response time. The findings demonstrate that the combination of block-induced flow-field modifications and auxiliary-inlet-mediated flow confinement effect significantly augments analyte transport to the sensor surface, thereby decreasing the sensor response time by approximately 92% in comparison to the scenario devoid of a block and auxiliary inlet. This study provides valuable insights for the design and optimization of point-of-care microfluidic devices with reduced detection time.

ACS Omega
National Institute Of Technology Silchar (IN), Birla Institute of Technology and Science - Hyderabad Campus (IN), Birla Institute of Technology and Science, Pilani (IN)
Department of Science and Technology, Ministry of Science and Technology, India, Birla Institute of Technology and Science, Pilani, Science and Engineering Research Board
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon