Wave-to-water energy balance of an S-shaped buoy and ball-screw power take-off driving small-scale batch reverse osmosis

Abstract Small wave energy converters can supply fresh water off the grid only if every link between the sea and the membrane is accounted for. This study couples a time-domain model of the S-shaped buoy SB-1.5 and its ball-screw power take-off (PTO), both experimentally verified in earlier work, with a batch seawater reverse osmosis (RO) model based on solution–diffusion transport, film-theory concentration polarisation, and Pitzer osmotic pressure. The PTO law is anchored to the published bench power and to a mean-to-peak ratio of 0.26 measured from the oscilloscope records, and the buoy follows the Cummins equation calibrated to the published 22 W full-scale absorbed power. In the ShiDao wave climate (2.0 kW/m), the unit absorbs 54.0 W (capture width ratio 1.83%), delivers 19.2 W of electricity and passes 7.3 W of hydraulic power to a 0.6 m² membrane element. With a batch cycle at 30% recovery, this gives about 142 L/day (51.7 m³/yr) at 0.83 g/L, whereas a fixed-pressure once-through module on the same chain gives 10.5 L/day. The hydraulic energy of 1.23 kWh/m³ is about 1.4 times the least work of separation, and the motor–pump set, at 48% stage efficiency, is the weakest link. Monte Carlo and Sobol analyses bound the output at 115–171 L/day (5–95%), with motor–pump efficiency alone explaining 58% of the variance. The simulation is calibrated to published bench tests and full-scale values, and sea trials are the next step. An unconstrained linear damper would absorb 2.6 times more power than the rating-limited PTO, and a 100 W generator raises the annual permeate from 51.7 to 79.6 m³. One unit provides 15 L/day per person for about nine people (volume only, before post-treatment), and eleven units cover a village of one hundred.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-17
DOI
https://doi.org/10.21203/rs.3.rs-11299333/v1
Primary Topic
Wave and Wind Energy Systems
Type
preprint

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Wave-to-water energy balance of an S-shaped buoy and ball-screw power take-off driving small-scale batch reverse osmosis

Touqeer Aslam, Christopher Nyangi Mkono, Zhongliang Meng, Jakiya Sultana et al.
1 links
Research Square
Wave and Wind Energy Systems
preprint

Wave-to-water energy balance of an S-shaped buoy and ball-screw power take-off driving small-scale batch reverse osmosis

Touqeer Aslam, Christopher Nyangi Mkono, Zhongliang Meng, Jakiya Sultana, Xidong Zhou, Dawood Majeed, Ammar Ahmed, Ali Azam, Mazedur Rahman, Zhichao Shen
preprint en

Abstract

Abstract Small wave energy converters can supply fresh water off the grid only if every link between the sea and the membrane is accounted for. This study couples a time-domain model of the S-shaped buoy SB-1.5 and its ball-screw power take-off (PTO), both experimentally verified in earlier work, with a batch seawater reverse osmosis (RO) model based on solution–diffusion transport, film-theory concentration polarisation, and Pitzer osmotic pressure. The PTO law is anchored to the published bench power and to a mean-to-peak ratio of 0.26 measured from the oscilloscope records, and the buoy follows the Cummins equation calibrated to the published 22 W full-scale absorbed power. In the ShiDao wave climate (2.0 kW/m), the unit absorbs 54.0 W (capture width ratio 1.83%), delivers 19.2 W of electricity and passes 7.3 W of hydraulic power to a 0.6 m² membrane element. With a batch cycle at 30% recovery, this gives about 142 L/day (51.7 m³/yr) at 0.83 g/L, whereas a fixed-pressure once-through module on the same chain gives 10.5 L/day. The hydraulic energy of 1.23 kWh/m³ is about 1.4 times the least work of separation, and the motor–pump set, at 48% stage efficiency, is the weakest link. Monte Carlo and Sobol analyses bound the output at 115–171 L/day (5–95%), with motor–pump efficiency alone explaining 58% of the variance. The simulation is calibrated to published bench tests and full-scale values, and sea trials are the next step. An unconstrained linear damper would absorb 2.6 times more power than the rating-limited PTO, and a 100 W generator raises the annual permeate from 51.7 to 79.6 m³. One unit provides 15 L/day per person for about nine people (volume only, before post-treatment), and eleven units cover a village of one hundred.

Research Square
Slovak University of Technology in Bratislava (SK), Qufu Normal University (CN), University of Miskolc (HU), South China University of Technology (CN)
Basic and Applied Basic Research Foundation of Guangdong Province
Affordable and clean energy, Clean water and sanitation
Wave and Wind Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon