Performance Assessment of a GEM-Based SXR Diagnostic System Operating in the WEST Plasma Environment

Robust soft X-ray (SXR) diagnostics are essential for impurity transport monitoring and real-time plasma control in long-pulse magnetic confinement fusion reactors designed for continuous baseload power generation. This study presents the instrumental validation and operational performance of a gas electron multiplier (GEM) diagnostic deployed on the fully metallic WEST tokamak. Specifically, the system features a radiation-hardened front-end capable of providing simultaneous 1D spatial (1 cm resolution) and spectrally resolved SXR measurements across ohmic and lower hybrid current drive (LHCD) discharges up to 1300 s. Absolute radiometric calibration is established using in situ 55Fe sources benchmarked against Geant4 Monte Carlo simulations, yielding spatial agreement within 1% and spectral count consistency within 2.9%. In ohmic discharges, experimental core emission profiles indicated varying degrees of impurity accumulation, requiring either uniform concentration scaling or artificially peaked tungsten spatial profiles to match synthetic coronal equilibrium projections. Conversely, LHCD-heated discharges exhibit impurity screening that flattens the radial emission profiles. The diagnostic isolates localized high-Z characteristic line radiation at the divertor strike points, initially identified as tungsten L-series and copper K-series, excited by suprathermal electron impact on solid targets. Coupled Geant4 and Garfield++ simulations demonstrate that the hard X-ray (HXR) background consists predominantly of single-strip clusters, confirming that secondary HXR interactions do not compromise signal interpretation in the primary 3–12 keV SXR window. Furthermore, core emission centroid tracking provides an internal constraint for magnetic equilibrium reconstructions, quantifying an in situ radial calibration offset of ~2 cm toward the low-field side.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-16
DOI
https://doi.org/10.3390/en19225543
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Performance Assessment of a GEM-Based SXR Diagnostic System Operating in the WEST Plasma Environment

Iraida N. Demchenko, Ewa Kowalska-Strzeciwilk, the WEST Team, Paweł Linczuk et al.
Energies
Magnetic confinement fusion research
article

Performance Assessment of a GEM-Based SXR Diagnostic System Operating in the WEST Plasma Environment

Iraida N. Demchenko, Ewa Kowalska-Strzeciwilk, the WEST Team, Paweł Linczuk, Karol Malinowski, Didier Mazon, Yevgen Melikhov, Maryna Chernyshova, Tomasz Czarski, Andrzej Wojeński, Grzegorz H. Kasprowicz, Denis Guibert, Michał Jagielski, Marcin Kastek
article en

Abstract

Robust soft X-ray (SXR) diagnostics are essential for impurity transport monitoring and real-time plasma control in long-pulse magnetic confinement fusion reactors designed for continuous baseload power generation. This study presents the instrumental validation and operational performance of a gas electron multiplier (GEM) diagnostic deployed on the fully metallic WEST tokamak. Specifically, the system features a radiation-hardened front-end capable of providing simultaneous 1D spatial (1 cm resolution) and spectrally resolved SXR measurements across ohmic and lower hybrid current drive (LHCD) discharges up to 1300 s. Absolute radiometric calibration is established using in situ 55Fe sources benchmarked against Geant4 Monte Carlo simulations, yielding spatial agreement within 1% and spectral count consistency within 2.9%. In ohmic discharges, experimental core emission profiles indicated varying degrees of impurity accumulation, requiring either uniform concentration scaling or artificially peaked tungsten spatial profiles to match synthetic coronal equilibrium projections. Conversely, LHCD-heated discharges exhibit impurity screening that flattens the radial emission profiles. The diagnostic isolates localized high-Z characteristic line radiation at the divertor strike points, initially identified as tungsten L-series and copper K-series, excited by suprathermal electron impact on solid targets. Coupled Geant4 and Garfield++ simulations demonstrate that the hard X-ray (HXR) background consists predominantly of single-strip clusters, confirming that secondary HXR interactions do not compromise signal interpretation in the primary 3–12 keV SXR window. Furthermore, core emission centroid tracking provides an internal constraint for magnetic equilibrium reconstructions, quantifying an in situ radial calibration offset of ~2 cm toward the low-field side.

EnergiesVol. 19(22)
Warsaw University of Technology (PL), National Centre for Nuclear Research (PL), Institute of Fundamental Technological Research (PL), Institut de Recherche sur la Fusion par confinement Magnétique (FR), Institute of Plasma Physics and Laser Microfusion (PL), Polish Academy of Sciences (PL)
Magnetic confinement fusion research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon