An Implantable In‐Tube System for Quantitative Precision Vagus Neuromodulation and Feedback of Intestinal Motility
ABSTRACT Electrical vagus neuromodulation of intestinal motility has demonstrated significant clinical utility in the field, where targeting the brain–gut axis can serve as an adjunct in treating intestinal diseases. However, quantitatively understanding vagus‐intestine interoceptive information about real‐time and in situ feedback on intestinal motility under the influence of electrical stimulation parameters is one of the most urgent challenges. Here we propose an implantable closed‐loop system that combines a scalable catheter‐type ionic piezoelectric (in‐tube) sensor as diverse as the gut, a microelectronic chip, an electrical vagus stimulation electrode, and a display interface to realize point‐of‐care precision vagus neuromodulation and feedback of intestinal motility. Owing to the radial gradient hydrogel structure design and stress concentration effect, the in‐tube sensor can simultaneously quantitatively detect and display four key parameters of intestinal motility, including intensity, frequency, duration, and local compression rate, with a high sensitivity of 7.0 mV mmHg −1 and unique pressure–time integral behavior with a time sensitivity of 24.1 mV s −1 , making up for the deficiency of traditional sensors that cannot obtain pressure duration. After implanting the in‐tube sensor in the anatomically challenging intestinal lumen of rabbits, we intuitively show how electrical vagus stimulation affects intestinal motility, which guides the optimal frequency window of 5 ∼ 10 Hz.
Authors
- Lihao Zhou (ORCID: https://orcid.org/0009-0003-1224-087X)
- Guozhen Shen (ORCID: https://orcid.org/0000-0002-9755-1647)
- Zhongyi Duan (ORCID: https://orcid.org/0009-0008-5804-3587)
- La Li (ORCID: https://orcid.org/0000-0001-7355-0407)
- Kai Jiang (ORCID: https://orcid.org/0000-0002-5411-2724)
- Zhongming Chen (ORCID: https://orcid.org/0000-0002-7495-1365)
- Lifeng Wu (ORCID: https://orcid.org/0000-0002-5238-8823)
- Weijia Liu (ORCID: https://orcid.org/0000-0002-7684-5777)
- Haiqing Liu
- Kaiwen Yang
- Di Chen
- Zhijian Du (ORCID: https://orcid.org/0009-0006-5521-5481)
- Xiangyu Sheng (ORCID: https://orcid.org/0009-0009-8262-6018)
- Haoyu Wu (ORCID: https://orcid.org/0009-0000-7399-821X)
Institutions
- Beijing Institute of Technology (CN)
- Chinese PLA General Hospital (CN)
- Chinese People's Liberation Army (CN)
Publication Details
- Journal
- Advanced Materials
- Published
- 2026-11-17
- DOI
- https://doi.org/10.1002/adma.75738
- Primary Topic
- Advanced Sensor and Energy Harvesting Materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China
- Natural Science Foundation of Beijing Municipality