Explainable hybrid CNN–transformer with fuzzy feature optimization for thyroid nodule malignancy classification on ultrasound

Abstract Thyroid nodule malignancy classification using ultrasound remains challenging owing to the differences in assessment by TI-RADS among different observers as well as the lack of interpretability in deep learning models. This study proposes a framework that is based on hybrid CNN-Transformer architecture with fuzzy feature optimization and visual explanation. This system combines convolution feature extraction, Transformer modeling, fuzzy membership feature selection, Softmax classifier, and Grad-CAM explanation. Model training was done using the TG3K+TN3K dataset, whereas DDTI, AUITD-Algerian, and micro-lesion synthetic dataset were used for testing. The performance evaluation of the model included classification metrics, cross-dataset testing, TI-RADS feature alignment, probability calibration, ablation testing, computation speed, and reader study by three radiologists. The model based on the suggested framework attained 91.8% accuracy, 89.8% sensitivity, 93.0% specificity, and 90.5% F1-score, along with an ROC-AUC of 0.932 and an inference time of 0.54 s per image. The use of Grad-CAM resulted in 82.85% mean feature alignment with TI-RADS region annotations by radiologists. Diagnostic accuracy increased by 9% points with the use of the assistance of AI. The calibration of probability led to a decrease in expected calibration error from 11.6 to 3.8%. However, factors such as disparities between the datasets used, the retrospective manner in which evaluation was done, and the use of artificial perturbations are some of the reasons why there is no immediate application of these findings into practice. This is because further prospective validation from multicenter studies is necessary to confirm clinical applicability of the results.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-16
DOI
https://doi.org/10.1038/s41598-026-80025-y
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Explainable hybrid CNN–transformer with fuzzy feature optimization for thyroid nodule malignancy classification on ultrasound

R. Yasir Abdullah, Barakkath Nisha U, P. Mano Paul, J. Rejina Parvin et al.
2 links
Scientific Reports
AI in cancer detection
article

Explainable hybrid CNN–transformer with fuzzy feature optimization for thyroid nodule malignancy classification on ultrasound

R. Yasir Abdullah, Barakkath Nisha U, P. Mano Paul, J. Rejina Parvin, Ignisha Rajathi G, I. Diana Jeba Jingle
article en

Abstract

Abstract Thyroid nodule malignancy classification using ultrasound remains challenging owing to the differences in assessment by TI-RADS among different observers as well as the lack of interpretability in deep learning models. This study proposes a framework that is based on hybrid CNN-Transformer architecture with fuzzy feature optimization and visual explanation. This system combines convolution feature extraction, Transformer modeling, fuzzy membership feature selection, Softmax classifier, and Grad-CAM explanation. Model training was done using the TG3K+TN3K dataset, whereas DDTI, AUITD-Algerian, and micro-lesion synthetic dataset were used for testing. The performance evaluation of the model included classification metrics, cross-dataset testing, TI-RADS feature alignment, probability calibration, ablation testing, computation speed, and reader study by three radiologists. The model based on the suggested framework attained 91.8% accuracy, 89.8% sensitivity, 93.0% specificity, and 90.5% F1-score, along with an ROC-AUC of 0.932 and an inference time of 0.54 s per image. The use of Grad-CAM resulted in 82.85% mean feature alignment with TI-RADS region annotations by radiologists. Diagnostic accuracy increased by 9% points with the use of the assistance of AI. The calibration of probability led to a decrease in expected calibration error from 11.6 to 3.8%. However, factors such as disparities between the datasets used, the retrospective manner in which evaluation was done, and the use of artificial perturbations are some of the reasons why there is no immediate application of these findings into practice. This is because further prospective validation from multicenter studies is necessary to confirm clinical applicability of the results.

Scientific Reports
Manipal Academy of Higher Education (IN), Dayananda Sagar Academy of Technology and Management (IN), Christ University (IN)
Good health and well-being
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon