Effects of operator experience and measurement depth on skeletal muscle shear wave elastography

PURPOSE: To investigate the effects of operator experience and measurement depth on shear wave elastography (SWE) measurements of skeletal muscle. Specifically, this study evaluated the reliability and agreement of SWE measurements obtained by experienced and inexperienced operators and examined whether patterns of shear wave velocity (SWV) across the region of interest (ROI) differed among muscles. METHODS: Twenty healthy young adults (40 limbs) participated in the study. SWE measurements were obtained from the biceps brachii (BB), triceps brachii (TB), rectus femoris (RF), and biceps femoris (BF) using a diagnostic ultrasound system. Two operators with different levels of ultrasound experience performed the measurements. Intra- and inter-rater reliability were assessed using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. SWV was compared among superficial, intermediate, and deep positions within a fixed-size ROI; these positions were defined relative to the ROI rather than by absolute tissue depth from the skin surface. RESULTS: Intra-rater reliability was good to excellent (ICC (1,3) = 0.767-0.962), while inter-rater reliability ranged from moderate to excellent (ICC (2,2) = 0.706-0.956). Bland-Altman analysis revealed no fixed or proportional biases. Significant positional differences were found in the BB, TB, and RF, but not in the BF. SWV was higher at deeper ROI positions in the BB and TB, whereas the RF showed lower SWV in the deep position. CONCLUSIONS: Comparable reliability was observed between experienced and inexperienced operators. The pattern of SWV across the ROI differed among muscles, indicating muscle-specific regional variation in SWE measurements. These findings may contribute to the standardization of skeletal muscle SWE.

Authors

Institutions

Publication Details

Journal
Journal of Ultrasound
Published
2026-11-16
DOI
https://doi.org/10.1007/s40477-026-01230-z
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effects of operator experience and measurement depth on skeletal muscle shear wave elastography

Mitsugu Yoneda, Tetsuo Ota, Hina Yoshida
2 links
Journal of Ultrasound
Ultrasound Imaging and Elastography
article

Effects of operator experience and measurement depth on skeletal muscle shear wave elastography

Mitsugu Yoneda, Tetsuo Ota, Hina Yoshida
article en

Abstract

PURPOSE: To investigate the effects of operator experience and measurement depth on shear wave elastography (SWE) measurements of skeletal muscle. Specifically, this study evaluated the reliability and agreement of SWE measurements obtained by experienced and inexperienced operators and examined whether patterns of shear wave velocity (SWV) across the region of interest (ROI) differed among muscles. METHODS: Twenty healthy young adults (40 limbs) participated in the study. SWE measurements were obtained from the biceps brachii (BB), triceps brachii (TB), rectus femoris (RF), and biceps femoris (BF) using a diagnostic ultrasound system. Two operators with different levels of ultrasound experience performed the measurements. Intra- and inter-rater reliability were assessed using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. SWV was compared among superficial, intermediate, and deep positions within a fixed-size ROI; these positions were defined relative to the ROI rather than by absolute tissue depth from the skin surface. RESULTS: Intra-rater reliability was good to excellent (ICC (1,3) = 0.767-0.962), while inter-rater reliability ranged from moderate to excellent (ICC (2,2) = 0.706-0.956). Bland-Altman analysis revealed no fixed or proportional biases. Significant positional differences were found in the BB, TB, and RF, but not in the BF. SWV was higher at deeper ROI positions in the BB and TB, whereas the RF showed lower SWV in the deep position. CONCLUSIONS: Comparable reliability was observed between experienced and inexperienced operators. The pattern of SWV across the ROI differed among muscles, indicating muscle-specific regional variation in SWE measurements. These findings may contribute to the standardization of skeletal muscle SWE.

Journal of Ultrasound
Kanazawa University (JP), Kanazawa Medical University (JP)
Kanazawa University, Japan Society for the Promotion of Science
Good health and well-being
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon