A Hybrid-Cycle OTEC Plant Joining Flash Steam to an Ammonia Bottoming Loop, Sized by Staged Budgets

Warm seawater first flashes to steam that preheats and evaporates ammonia for a closed bottoming turbine, combining open-cycle water production with closed-cycle machinery compactness in one staged plant, a computed study of the arrangement. Its operating principle: hybrid-cycle plant, where flash steam raises the ammonia loop's evaporation temperature so the turbine stays compact while the flash chamber still yields fresh water. Headline values are hyb surface temperature hyb c = 27; hyb deep temperature hyb c = 5; hyb temperature difference hyb k = 22; hyb carnot efficiency hyb percent = 7.33; hyb adopted cycle hyb efficiency percent = 3.811; hyb warm flow hyb m3 per s hyb = 80. Staging buys compactness without surrendering the water: the flash chamber does double duty as evaporator and still. SIMULATED, NOT MEASURED. City residents drinking its water and using its power are the only beneficiaries contemplated here. The design is municipal infrastructure, conceived for public supply, with no application to harm of any kind.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24291455
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Hybrid-Cycle OTEC Plant Joining Flash Steam to an Ammonia Bottoming Loop, Sized by Staged Budgets

William Alexander Aldred
12 links
Zenodo (CERN European Organization for Nuclear Research)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

A Hybrid-Cycle OTEC Plant Joining Flash Steam to an Ammonia Bottoming Loop, Sized by Staged Budgets

William Alexander Aldred
article en

Abstract

Warm seawater first flashes to steam that preheats and evaporates ammonia for a closed bottoming turbine, combining open-cycle water production with closed-cycle machinery compactness in one staged plant, a computed study of the arrangement. Its operating principle: hybrid-cycle plant, where flash steam raises the ammonia loop's evaporation temperature so the turbine stays compact while the flash chamber still yields fresh water. Headline values are hyb surface temperature hyb c = 27; hyb deep temperature hyb c = 5; hyb temperature difference hyb k = 22; hyb carnot efficiency hyb percent = 7.33; hyb adopted cycle hyb efficiency percent = 3.811; hyb warm flow hyb m3 per s hyb = 80. Staging buys compactness without surrendering the water: the flash chamber does double duty as evaporator and still. SIMULATED, NOT MEASURED. City residents drinking its water and using its power are the only beneficiaries contemplated here. The design is municipal infrastructure, conceived for public supply, with no application to harm of any kind.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy, Climate action
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon