Economic Assessment of Pipe-Network Thermal Storage in Fifth-Generation District Heating and Cooling Systems

Fifth-generation district heating and cooling (5GDHC) systems have attracted increasing attention because they can supply heating and cooling simultaneously, enable buildings to act as thermal prosumers, and facilitate the recovery of low-grade waste heat. Because these networks operate near ambient temperature, their temperature can be modulated over a relatively wide range in both winter and summer, creating the potential to use the pipe network for both heat and cold storage. However, the economic value of using this inherent thermal capacity and the benefit of increasing it through pipe enlargement remain unclear. This study develops a dynamic thermo-hydraulic optimization framework that represents bidirectional flow, water and ground thermal states, temperature-dependent heat-pump and chiller performance, pumping electricity, and annualized system costs. A genetic algorithm is used offline to compare daily-constant and predictive network-temperature control at three pipe-capacity levels in a synthetic 5GDHC system developed using Beijing weather and tariff data. Predictive control reduced the annualized cost at all three pipe-capacity levels, with savings ranging from 0.17% to 0.52%. Reductions in monthly demand charges and active-equipment capacity costs provided most of the economic benefit, whereas the energy charge changed only slightly or increased. Increasing every pipe by one or two catalog sizes raised the network water volume by 32.1% and 69.5% and reduced pumping electricity by 51.8% and 74.0%, but increased the annualized cost by 0.14% and 0.44%, respectively. The results show that the thermal capacity already available in a 5GDHC network can provide modest operational flexibility, but enlarging pipes solely to obtain additional thermal storage did not show a substantial economic advantage in the investigated case.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-16
DOI
https://doi.org/10.3390/buildings16224569
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Economic Assessment of Pipe-Network Thermal Storage in Fifth-Generation District Heating and Cooling Systems

Lingqi Su, Yongming Zhang, Shanshou Li
1 links
Buildings
Integrated Energy Systems Optimization
article

Economic Assessment of Pipe-Network Thermal Storage in Fifth-Generation District Heating and Cooling Systems

Lingqi Su, Yongming Zhang, Shanshou Li
article en

Abstract

Fifth-generation district heating and cooling (5GDHC) systems have attracted increasing attention because they can supply heating and cooling simultaneously, enable buildings to act as thermal prosumers, and facilitate the recovery of low-grade waste heat. Because these networks operate near ambient temperature, their temperature can be modulated over a relatively wide range in both winter and summer, creating the potential to use the pipe network for both heat and cold storage. However, the economic value of using this inherent thermal capacity and the benefit of increasing it through pipe enlargement remain unclear. This study develops a dynamic thermo-hydraulic optimization framework that represents bidirectional flow, water and ground thermal states, temperature-dependent heat-pump and chiller performance, pumping electricity, and annualized system costs. A genetic algorithm is used offline to compare daily-constant and predictive network-temperature control at three pipe-capacity levels in a synthetic 5GDHC system developed using Beijing weather and tariff data. Predictive control reduced the annualized cost at all three pipe-capacity levels, with savings ranging from 0.17% to 0.52%. Reductions in monthly demand charges and active-equipment capacity costs provided most of the economic benefit, whereas the energy charge changed only slightly or increased. Increasing every pipe by one or two catalog sizes raised the network water volume by 32.1% and 69.5% and reduced pumping electricity by 51.8% and 74.0%, but increased the annualized cost by 0.14% and 0.44%, respectively. The results show that the thermal capacity already available in a 5GDHC network can provide modest operational flexibility, but enlarging pipes solely to obtain additional thermal storage did not show a substantial economic advantage in the investigated case.

BuildingsVol. 16(22)
Tongji University (CN), Anhui Jianzhu University (CN)
Affordable and clean energy, Climate action, Industry, innovation and infrastructure
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon