Ocular Complications Related to Iris-Fixated Phakic Intraocular Lens Implantation: A Systematic Review and Meta-Analysis

TOPIC: This systematic review and meta-analysis evaluated the cumulative prevalence of ocular complications following implantation of Artisan®/Verisyse® iris-fixated phakic intraocular lenses in adult patients undergoing refractive surgery. Outcomes included postoperative ocular complications and longitudinal loss of endothelial cell density (ECD). CLINICAL RELEVANCE: Phakic intraocular lenses are widely used to correct moderate-to-high refractive errors. Available evidence on complication rates is heterogeneous and often limited to narrative reports, hindering accurate risk counseling and long-term clinical decision-making. METHODS: This study was conducted according to PRISMA guidelines and was registered in PROSPERO (CRD420251150677). Eligible studies included ≥10 eyes implanted with Artisan®/Verisyse® lenses reporting postoperative complications. Risk of bias was assessed using design-specific tools. Proportion meta-analyses were performed with subgroup analyses comparing real-world evidence studies versus clinical trials. ECD loss was analyzed from three months to 10 years post-implantation. Certainty of evidence was evaluated using GRADE. RESULTS: Fifty-five studies were included. Iris atrophy was the most common complication (20.3%, 95% CI: 5.7-52.1). Other complications included pupil ovalization (7.6%, 95% CI: 4.8-12.5), progressive reduction in visual acuity (7.6%, 95% CI: 5.8-9.5), position-related complications (including rotation, dislocation, subluxation, and luxation) (6.7%, 95% CI: 1.9-33.4), uveitis (6.2%, 95% CI: 4.3-9.1), and halos (5.3%, 95% CI: 3.2-7.9). Ocular hypertension (4.7%, 95% CI: 2.4-7.9), cataract (2.8%, 95% CI: 1.6-3.5), corneal decompensation (2.6%, 95% CI: 1.8-6.5), and retinal detachment (1.1%, 95% CI: 0.7-1.3) occurred less frequently. Subgroup analyses showed higher rates of corneal decompensation in real-world studies (4.2% vs. 1.3%; p = 0.04) and traumatic position-related complications (5.0% vs. 0.8%; p = 0.02), whereas ocular hypertension was more frequent in clinical trials (14.1% vs. 2.3%; p < 0.01). ECD loss increased from 5.3% at 3 months to 15.8% at 10 years. Certainty of evidence ranged from very low to moderate, with substantial heterogeneity across outcomes. CONCLUSION: Despite overall acceptable safety, Artisan®/Verisyse® implantation is associated with measurable ocular complications and progressive ECD loss.

Authors

Institutions

Publication Details

Journal
Journal of Cataract & Refractive Surgery
Published
2026-11-16
DOI
https://doi.org/10.1097/j.jcrs.0000000000002110
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Ocular Complications Related to Iris-Fixated Phakic Intraocular Lens Implantation: A Systematic Review and Meta-Analysis

Danna Lesley Cruz Reyes, Paula Alejandra Navarro, Lizeth Catherine Rodríguez-Corredor, Germán Mejía‐Salgado et al.
Journal of Cataract & Refractive Surgery
Intraocular Surgery and Lenses
article

Ocular Complications Related to Iris-Fixated Phakic Intraocular Lens Implantation: A Systematic Review and Meta-Analysis

Danna Lesley Cruz Reyes, Paula Alejandra Navarro, Lizeth Catherine Rodríguez-Corredor, Germán Mejía‐Salgado, Alejandro Tello, Rubén D. Berrospi, Juan Daniel Ribero, Diana Carolina Cortés Jaimes, Joaquín Alonso Pérez-Vivas, Laura Daniela Rodríguez-Camelo, Blanca Aguilar-Barrera, Santiago Espinosa-Lugo, Virgilio Galvis, Ana María Núñez-Pardo
article en

Abstract

TOPIC: This systematic review and meta-analysis evaluated the cumulative prevalence of ocular complications following implantation of Artisan®/Verisyse® iris-fixated phakic intraocular lenses in adult patients undergoing refractive surgery. Outcomes included postoperative ocular complications and longitudinal loss of endothelial cell density (ECD). CLINICAL RELEVANCE: Phakic intraocular lenses are widely used to correct moderate-to-high refractive errors. Available evidence on complication rates is heterogeneous and often limited to narrative reports, hindering accurate risk counseling and long-term clinical decision-making. METHODS: This study was conducted according to PRISMA guidelines and was registered in PROSPERO (CRD420251150677). Eligible studies included ≥10 eyes implanted with Artisan®/Verisyse® lenses reporting postoperative complications. Risk of bias was assessed using design-specific tools. Proportion meta-analyses were performed with subgroup analyses comparing real-world evidence studies versus clinical trials. ECD loss was analyzed from three months to 10 years post-implantation. Certainty of evidence was evaluated using GRADE. RESULTS: Fifty-five studies were included. Iris atrophy was the most common complication (20.3%, 95% CI: 5.7-52.1). Other complications included pupil ovalization (7.6%, 95% CI: 4.8-12.5), progressive reduction in visual acuity (7.6%, 95% CI: 5.8-9.5), position-related complications (including rotation, dislocation, subluxation, and luxation) (6.7%, 95% CI: 1.9-33.4), uveitis (6.2%, 95% CI: 4.3-9.1), and halos (5.3%, 95% CI: 3.2-7.9). Ocular hypertension (4.7%, 95% CI: 2.4-7.9), cataract (2.8%, 95% CI: 1.6-3.5), corneal decompensation (2.6%, 95% CI: 1.8-6.5), and retinal detachment (1.1%, 95% CI: 0.7-1.3) occurred less frequently. Subgroup analyses showed higher rates of corneal decompensation in real-world studies (4.2% vs. 1.3%; p = 0.04) and traumatic position-related complications (5.0% vs. 0.8%; p = 0.02), whereas ocular hypertension was more frequent in clinical trials (14.1% vs. 2.3%; p < 0.01). ECD loss increased from 5.3% at 3 months to 15.8% at 10 years. Certainty of evidence ranged from very low to moderate, with substantial heterogeneity across outcomes. CONCLUSION: Despite overall acceptable safety, Artisan®/Verisyse® implantation is associated with measurable ocular complications and progressive ECD loss.

Journal of Cataract & Refractive Surgery
Universidad Industrial de Santander (CO), Universidad Autónoma de Bucaramanga (CO), Universidad Nacional de Colombia (CO), Foscal Hospital (CO), Universidad del Rosario (CO)
Good health and well-being
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon