Behaviour of bare and protected unbraced steel pitched frame shed in fire

Purpose The purpose of this study is to assess the thermo-mechanical behaviour of an unbraced steel pitched-frame shed exposed to non-uniform fire and evaluate the effectiveness of gypsum board as passive fire protection. Investigation of the effect of three exposure scenarios on temperature, stress and deformation and identification of minimum coating thickness to maintain mechanical performance within IS 800:2007 limits were carried out. Design/methodology/approach A 3-D finite element model of an E250 steel pitched-frame shed was generated in Abaqus software using two-step analysis process comprising heat transfer analysis followed by structural analysis. A 30 min ISO 834 standard fire was considered for three exposure scenarios, namely one-side column, half-roof and full-roof exposures. The temperature-dependent properties of steel were considered, and the mechanical response of the frame was evaluated. A parametric study of 10, 20 and 30 mm gypsum board thicknesses was carried out to examine its effect on temperature, stress and displacement. Findings Fire exposure considerably elevated the temperature, stress and displacement of the unprotected frame. The peak temperatures obtained were 803.5, 796.5 and 796.5°C for three exposure cases which were beyond admissible limits. The application of 30?mm gypsum board reduced the peak temperature by 87.3%, which in turn reduced the stress and displacement to within the allowable limits for all cases. Originality/value A whole-structure analysis was carried out for non-uniform fire exposure scenarios. The thickness of minimum gypsum board required to protect the steel frame shed from fire was identified. The study provides a benchmark for similar structures.

Authors

Publication Details

Journal
Journal of Structural Fire Engineering
Published
2026-11-16
DOI
https://doi.org/10.1108/jsfe-08-2026-0034
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Behaviour of bare and protected unbraced steel pitched frame shed in fire

Archana Bohra Gupta, Kuldeep Joshi
2 links
Journal of Structural Fire Engineering
Fire effects on concrete materials
article

Behaviour of bare and protected unbraced steel pitched frame shed in fire

Archana Bohra Gupta, Kuldeep Joshi
article en

Abstract

Purpose The purpose of this study is to assess the thermo-mechanical behaviour of an unbraced steel pitched-frame shed exposed to non-uniform fire and evaluate the effectiveness of gypsum board as passive fire protection. Investigation of the effect of three exposure scenarios on temperature, stress and deformation and identification of minimum coating thickness to maintain mechanical performance within IS 800:2007 limits were carried out. Design/methodology/approach A 3-D finite element model of an E250 steel pitched-frame shed was generated in Abaqus software using two-step analysis process comprising heat transfer analysis followed by structural analysis. A 30 min ISO 834 standard fire was considered for three exposure scenarios, namely one-side column, half-roof and full-roof exposures. The temperature-dependent properties of steel were considered, and the mechanical response of the frame was evaluated. A parametric study of 10, 20 and 30 mm gypsum board thicknesses was carried out to examine its effect on temperature, stress and displacement. Findings Fire exposure considerably elevated the temperature, stress and displacement of the unprotected frame. The peak temperatures obtained were 803.5, 796.5 and 796.5°C for three exposure cases which were beyond admissible limits. The application of 30?mm gypsum board reduced the peak temperature by 87.3%, which in turn reduced the stress and displacement to within the allowable limits for all cases. Originality/value A whole-structure analysis was carried out for non-uniform fire exposure scenarios. The thickness of minimum gypsum board required to protect the steel frame shed from fire was identified. The study provides a benchmark for similar structures.

Journal of Structural Fire Engineering
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon