Numerical Investigation Of Passive Microfluidic Mixer Geometries: Mixing Performance And Pressure-Drop Trade-Offs

Passive microfluidic mixers provide a compact solution for improving species mixing in microscale flow systems without external actuation.However, improved mixing often comes at the cost of a higher pressure drop.In this work, numerical investigations are conducted for five distinct passive microfluidic mixer geometries: a baseline empty chamber, a chamber with circular obstacles, a chamber with X-shaped obstacles, a hybrid configuration with vertical and horizontal baffles, and a configuration with alternating rectangular baffles.We built the two-dimensional models in COMSOL Multiphysics using the Laminar Flow and Transport of Diluted Species interfaces.We performed steady-state simulations at different inlet velocities and studied the velocity distributions, concentration fields, mixing performance, and pressure drop.We evaluated mixing performance using a variance-based mixing index at five normalized axial locations in the chamber, and we obtained the pressure drop from the difference between the average inlet and outlet pressures.At the reference inlet velocity of 0.001 m/s, the hybrid-baffle and rectangular-baffle configurations achieved outlet mixing indices of approximately 0.9992 and 0.999999, respectively.However, their corresponding pressure drops were 144.25 Pa and 897.67 Pa, compared with 0.44 Pa for the empty baseline chamber.The results show substantial differences in the mixing performance and hydraulic resistance of the geometries investigated.The hybrid-baffle configuration achieved near-unity mixing with a lower pressure drop than the rectangular-baffle configuration, whereas the latter produced the highest outlet mixing index among the designs investigated.Converged solutions were not obtained for the circular-obstacle and X-shaped-obstacle configurations at the lowest inlet velocity of 0.0005 m/s; these cases were excluded from comparisons at that condition.This comparative numerical study provides a basis for evaluating passive micromixer geometries in terms of mixing performance and pressure-drop requirements.

Authors

Institutions

Publication Details

Journal
Journal of Fluid Flow Heat and Mass Transfer
Published
2026-11-16
DOI
https://doi.org/10.11159/jffhmt.2026.038
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Numerical Investigation Of Passive Microfluidic Mixer Geometries: Mixing Performance And Pressure-Drop Trade-Offs

Navyasri Narmeta, Hari Krishnan Narayanan Unni
Journal of Fluid Flow Heat and Mass Transfer
Microfluidic and Capillary Electrophoresis Applications
article

Numerical Investigation Of Passive Microfluidic Mixer Geometries: Mixing Performance And Pressure-Drop Trade-Offs

Navyasri Narmeta, Hari Krishnan Narayanan Unni
article en

Abstract

Passive microfluidic mixers provide a compact solution for improving species mixing in microscale flow systems without external actuation.However, improved mixing often comes at the cost of a higher pressure drop.In this work, numerical investigations are conducted for five distinct passive microfluidic mixer geometries: a baseline empty chamber, a chamber with circular obstacles, a chamber with X-shaped obstacles, a hybrid configuration with vertical and horizontal baffles, and a configuration with alternating rectangular baffles.We built the two-dimensional models in COMSOL Multiphysics using the Laminar Flow and Transport of Diluted Species interfaces.We performed steady-state simulations at different inlet velocities and studied the velocity distributions, concentration fields, mixing performance, and pressure drop.We evaluated mixing performance using a variance-based mixing index at five normalized axial locations in the chamber, and we obtained the pressure drop from the difference between the average inlet and outlet pressures.At the reference inlet velocity of 0.001 m/s, the hybrid-baffle and rectangular-baffle configurations achieved outlet mixing indices of approximately 0.9992 and 0.999999, respectively.However, their corresponding pressure drops were 144.25 Pa and 897.67 Pa, compared with 0.44 Pa for the empty baseline chamber.The results show substantial differences in the mixing performance and hydraulic resistance of the geometries investigated.The hybrid-baffle configuration achieved near-unity mixing with a lower pressure drop than the rectangular-baffle configuration, whereas the latter produced the highest outlet mixing index among the designs investigated.Converged solutions were not obtained for the circular-obstacle and X-shaped-obstacle configurations at the lowest inlet velocity of 0.0005 m/s; these cases were excluded from comparisons at that condition.This comparative numerical study provides a basis for evaluating passive micromixer geometries in terms of mixing performance and pressure-drop requirements.

Journal of Fluid Flow Heat and Mass TransferVol. 13
Indian Institute of Technology Hyderabad (IN)
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon