Simple topology does most of the work: a pre-registered evaluation of label-free triage for critical failures in coronary CTA segmentation

Automated coronary artery segmentation from CT angiography (CCTA) can fail in ways that matter clinically, such as a missed proximal vessel, a broken trunk or a leak into a vein, while still reaching a high Dice score. We study label-free review triage: ranking reconstructions without ground truth so that reviewing a fixed 20% of scans catches as many anatomically critical failures as possible. We define a reference-based taxonomy of critical failures, pre-register an analysis plan with explicit success criteria, select one model on development data (a regularised logistic model over mask-derived graph, ostium and shape-plausibility features) and evaluate it once on a sealed test set of 160 patients (ImageCAS-X), segmented by a model it never saw. The frozen model reached a normalised recall of 0.906 at the 20% budget, catching 29 of the 32 critical failures that were catchable at that budget (29 of 64 in total) with precision 0.91. It met the pre-registered comparison with ensemble-agreement quality control. Its gain over the best pre-specified single-feature rule was +12.5 pp (95% CI -0.3 to +23.9), narrowly missing the pre-registered superiority criterion. In pre-registered follow-up analyses, the gain replicated across five nnU-Net folds (+11.4 pp, 95% CI +3.0 to +20.7; same patients), shrank or vanished when the input CTs were degraded, and was matched by an exploratory fragmentation feature. Simple, anatomy-aware topology features capture most of the achievable triage value; a learned combination adds a small, directionally consistent but fragile increment. We report every criterion, three negative findings and the full pre-registration trail, and release the code. Code: https://github.com/vhmaadhav/coronarysafe

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-16
DOI
https://doi.org/10.5281/zenodo.24269057
Primary Topic
Medical Image Segmentation Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Simple topology does most of the work: a pre-registered evaluation of label-free triage for critical failures in coronary CTA segmentation

Maadhav V H
2 links
Zenodo (CERN European Organization for Nuclear Research)
Medical Image Segmentation Techniques
preprint

Simple topology does most of the work: a pre-registered evaluation of label-free triage for critical failures in coronary CTA segmentation

Maadhav V H
preprint en

Abstract

Automated coronary artery segmentation from CT angiography (CCTA) can fail in ways that matter clinically, such as a missed proximal vessel, a broken trunk or a leak into a vein, while still reaching a high Dice score. We study label-free review triage: ranking reconstructions without ground truth so that reviewing a fixed 20% of scans catches as many anatomically critical failures as possible. We define a reference-based taxonomy of critical failures, pre-register an analysis plan with explicit success criteria, select one model on development data (a regularised logistic model over mask-derived graph, ostium and shape-plausibility features) and evaluate it once on a sealed test set of 160 patients (ImageCAS-X), segmented by a model it never saw. The frozen model reached a normalised recall of 0.906 at the 20% budget, catching 29 of the 32 critical failures that were catchable at that budget (29 of 64 in total) with precision 0.91. It met the pre-registered comparison with ensemble-agreement quality control. Its gain over the best pre-specified single-feature rule was +12.5 pp (95% CI -0.3 to +23.9), narrowly missing the pre-registered superiority criterion. In pre-registered follow-up analyses, the gain replicated across five nnU-Net folds (+11.4 pp, 95% CI +3.0 to +20.7; same patients), shrank or vanished when the input CTs were degraded, and was matched by an exploratory fragmentation feature. Simple, anatomy-aware topology features capture most of the achievable triage value; a learned combination adds a small, directionally consistent but fragile increment. We report every criterion, three negative findings and the full pre-registration trail, and release the code. Code: https://github.com/vhmaadhav/coronarysafe

Zenodo (CERN European Organization for Nuclear Research)
KPR Institute of Engineering and Technology (IN)
Good health and well-being
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon