Porosity estimation of construction materials from computed tomography images using image segmentation and adaptive thresholding techniques

Computed tomography (CT) enables non-destructive examination of pore structures, but image-based porosity estimates depend on preprocessing, segmentation, and imaging resolution. This study compares four filtering–thresholding configurations for estimating porosity from 6,840 CT slices representing six construction-material classes: CM0, CM5, CM10, CM20, geopolymer mortar, and ultra-high-performance concrete (UHPC). Median and Gaussian filtering were paired separately with adaptive mean-C and adaptive Gaussian thresholding. Pore-area fractions were calculated from segmented images and compared with available vacuum-pycnometer (PYC) reference values. Three specimens per class were prepared from one batch and tested using PYC, with one specimen subsequently selected for CT scanning. Median filtering with adaptive mean-C thresholding (MB_AMCT) showed promising agreement with the supplied reference values for most investigated classes. In the UHPC comparison figure, all four configurations exceeded the PYC reference value, indicating that unresolved fine pores alone cannot explain the discrepancy. Contributions from noise, local intensity variations, threshold settings, pore misclassification, and physical-reference uncertainty may also contribute, and differences in pore accessibility and spatial coverage mean that CT and PYC cannot be directly equivalent. An additional qualitative comparison looked at candidate pore boundaries in five available CT crops, including UHPC, without independent segmentation ground truth. Agreement in total porosity does not establish accurate pore localization or morphology. Independent CT specimen replication, parameter-sensitivity analysis, and unfiltered comparisons were unavailable. The findings therefore describe performance within the investigated dataset. Further evaluation with documented parameters and independently prepared specimens is required to establish reproducibility, ranking stability, and broader applicability.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-17
DOI
https://doi.org/10.1038/s41598-026-78019-x
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Porosity estimation of construction materials from computed tomography images using image segmentation and adaptive thresholding techniques

Yuvaraj Natarajan, Bubryur Kim, Sungwoo Park, K. R. Sri Preethaa et al.
1 links
Scientific Reports
Concrete and Cement Materials Research
article

Porosity estimation of construction materials from computed tomography images using image segmentation and adaptive thresholding techniques

Yuvaraj Natarajan, Bubryur Kim, Sungwoo Park, K. R. Sri Preethaa, Sukhoon Pyo
article en

Abstract

Computed tomography (CT) enables non-destructive examination of pore structures, but image-based porosity estimates depend on preprocessing, segmentation, and imaging resolution. This study compares four filtering–thresholding configurations for estimating porosity from 6,840 CT slices representing six construction-material classes: CM0, CM5, CM10, CM20, geopolymer mortar, and ultra-high-performance concrete (UHPC). Median and Gaussian filtering were paired separately with adaptive mean-C and adaptive Gaussian thresholding. Pore-area fractions were calculated from segmented images and compared with available vacuum-pycnometer (PYC) reference values. Three specimens per class were prepared from one batch and tested using PYC, with one specimen subsequently selected for CT scanning. Median filtering with adaptive mean-C thresholding (MB_AMCT) showed promising agreement with the supplied reference values for most investigated classes. In the UHPC comparison figure, all four configurations exceeded the PYC reference value, indicating that unresolved fine pores alone cannot explain the discrepancy. Contributions from noise, local intensity variations, threshold settings, pore misclassification, and physical-reference uncertainty may also contribute, and differences in pore accessibility and spatial coverage mean that CT and PYC cannot be directly equivalent. An additional qualitative comparison looked at candidate pore boundaries in five available CT crops, including UHPC, without independent segmentation ground truth. Agreement in total porosity does not establish accurate pore localization or morphology. Independent CT specimen replication, parameter-sensitivity analysis, and unfiltered comparisons were unavailable. The findings therefore describe performance within the investigated dataset. Further evaluation with documented parameters and independently prepared specimens is required to establish reproducibility, ranking stability, and broader applicability.

Scientific Reports
Kyungpook National University (KR), Ulsan National Institute of Science and Technology (KR), Chung-Ang University (KR), Vellore Institute of Technology University (IN)
Kyungpook National University
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon