Leveraging Parameter Coupling for Signal Enhancement and Early Detection of Battery Thermal Runaway
Lithium-ion batteries are vital power sources, but the risk of thermal runaway remains a major safety concern. Existing sensor early-warning systems struggle to detect the localized and rapid evolution of internal failures, leading to inadequate time for preemptive intervention. Here, we present a thermal runaway sensor engineered with a temperature-pressure dual-signal coupling mechanism. The proposed strategy can capture the coupled temperature-pressure signals within the battery pack, thereby enabling the detection of the precursors of battery failure. The sensor can detect abnormal signals about 40 min before the thermal runaway. Translating lab research to industry, we integrated the sensor into commercial large-capacity 314 A h cells. Coupled with a custom-built data acquisition system, the system underwent rigorous validation over 12 months in an energy storage facility under actual conditions. The dual-signal sensing strategy offers an approach for early warning of battery thermal runaway in commercial energy storage systems.
Authors
- 相佳媛
- Zexiang Shen (ORCID: https://orcid.org/0000-0001-7432-7936)
- Minghua Chen (ORCID: https://orcid.org/0000-0001-6014-328X)
- Wenjie Zhao (ORCID: https://orcid.org/0000-0002-5524-1464)
- Weidong Bai
- Weifeng Zhang
- Yuan Yao
Institutions
- Harbin University of Science and Technology (CN)
- Nanyang Technological University (SG)
Publication Details
- Journal
- ACS Nano
- Published
- 2026-11-16
- DOI
- https://doi.org/10.1021/acsnano.6c11980
- Primary Topic
- Battery Modeling and Management
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China