Comparison of visual outcomes and optical performance between Eyhance ICB00 and Lentis Comfort LS-313 MF15 intraocular lenses

AIM: To compare the postoperative visual outcomes and optical performance of the Eyhance ICB00 and Lentis Comfort LS-313 MF15 intraocular lenses (IOLs). METHODS: Patients who underwent phacoemulsification with bilateral IOL implantation, receiving the ICB00 IOL in one eye and the LS-313 MF15 IOL in the fellow eye, were enrolled in this retrospective study. Postoperative visual acuities, including corrected distance visual acuity (CDVA) and intermediate and near visual acuities, and monocular and binocular defocus curves were measured. Postoperative incidences of visual disturbances were also assessed. Optical bench testing evaluated the modulation transfer function (MTF) values at various defocus levels. RESULTS: The study included 52 eyes from 26 patients (16 females; 61.5%) who underwent ICB00 IOL implantation in one eye (26 eyes) and LS-313 MF15 IOL implantation in the opposite eye (26 eyes). The mean patient age was 69.2±8.4y (range, 55–84y). Both IOLs achieved excellent postoperative CDVA of 20/20 or better without significant differences between groups (88.5% vs 92.3%). Intermediate and near visual acuity were better in the LS-313 MF15 group compared with the ICB00 group, whereas the frequency of glare, starbursts, and halos was comparable between groups. The binocular defocus curve demonstrated better visual performance across defocus levels compared with both monocular curves, and the LS-313 MF15 group showed better visual acuity than the ICB00 group at negative defocus levels. Optical bench testing demonstrated that the LS-313 MF15 IOL provided higher MTF values at negative defocus levels compared with the ICB00 IOL. CONCLUSION: The LS-313 MF15 IOL demonstrates a significant advantage over the ICB00 IOL regarding intermediate and near visual acuity. The LS-313 MF15 exhibits superior optical performance on bench testing, suggesting better functional outcomes for patients requiring a broader vision range.

Authors

Institutions

Publication Details

Journal
International Journal of Ophthalmology
Published
2026-11-16
DOI
https://doi.org/10.18240/ijo.2026.12.11
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of visual outcomes and optical performance between Eyhance ICB00 and Lentis Comfort LS-313 MF15 intraocular lenses

Youngbin Song, Minji Woo, Seul Ki Yang, Jinhwan Park et al.
3 links
International Journal of Ophthalmology
Intraocular Surgery and Lenses
article

Comparison of visual outcomes and optical performance between Eyhance ICB00 and Lentis Comfort LS-313 MF15 intraocular lenses

Youngbin Song, Minji Woo, Seul Ki Yang, Jinhwan Park, Hyun Sun Jeon, Youngsub Eom, Jong Suk Song, Dong Hyun Kim, Seong-Jae Kim
article en

Abstract

AIM: To compare the postoperative visual outcomes and optical performance of the Eyhance ICB00 and Lentis Comfort LS-313 MF15 intraocular lenses (IOLs). METHODS: Patients who underwent phacoemulsification with bilateral IOL implantation, receiving the ICB00 IOL in one eye and the LS-313 MF15 IOL in the fellow eye, were enrolled in this retrospective study. Postoperative visual acuities, including corrected distance visual acuity (CDVA) and intermediate and near visual acuities, and monocular and binocular defocus curves were measured. Postoperative incidences of visual disturbances were also assessed. Optical bench testing evaluated the modulation transfer function (MTF) values at various defocus levels. RESULTS: The study included 52 eyes from 26 patients (16 females; 61.5%) who underwent ICB00 IOL implantation in one eye (26 eyes) and LS-313 MF15 IOL implantation in the opposite eye (26 eyes). The mean patient age was 69.2±8.4y (range, 55–84y). Both IOLs achieved excellent postoperative CDVA of 20/20 or better without significant differences between groups (88.5% vs 92.3%). Intermediate and near visual acuity were better in the LS-313 MF15 group compared with the ICB00 group, whereas the frequency of glare, starbursts, and halos was comparable between groups. The binocular defocus curve demonstrated better visual performance across defocus levels compared with both monocular curves, and the LS-313 MF15 group showed better visual acuity than the ICB00 group at negative defocus levels. Optical bench testing demonstrated that the LS-313 MF15 IOL provided higher MTF values at negative defocus levels compared with the ICB00 IOL. CONCLUSION: The LS-313 MF15 IOL demonstrates a significant advantage over the ICB00 IOL regarding intermediate and near visual acuity. The LS-313 MF15 exhibits superior optical performance on bench testing, suggesting better functional outcomes for patients requiring a broader vision range.

International Journal of OphthalmologyVol. 19(12)
Korea University (KR), New Generation University College (ET), Hanwha Solutions (South Korea) (KR), Onnuri Smile Eye Clinic (KR)
Good health and well-being
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon