Surgical Stabilization of Rib Fractures With a Parallel-Hook Clamp System: A Retrospective Case Series of 18 Patients From a Brazilian Hospital

Introduction: Surgical stabilization of rib fractures (SSRF) is increasingly used for flail chest and severely displaced rib fractures, but data from Latin America on screwless clamp-type implants are scarce. This study describes the clinical profile, in-hospital outcomes, and patient-reported outcomes of patients who underwent SSRF with a parallel-hook clamp system. Methods: This retrospective case series included patients who underwent SSRF with a parallel-hook clamp system at a hospital in southern Brazil and who attended a follow-up visit and completed a structured interview. Data from medical records and interviews were analyzed descriptively, and missing data were not imputed. Results: Of 20 eligible patients, 18 were included (mean age 52.8 ± 13.4 years; 13 men, 72.2%). Car or motorcycle collisions caused 10 injuries (55.6%). A median of five ribs were fractured (range 1-7); 12 of 17 patients (70.6%) had multiple non-flail fractures, and three (17.6%) had flail chest. Twelve of 16 patients (75.0%) had a hemothorax or hemopneumothorax before surgery. Surgery was performed more than 72 hours after injury in 11 patients (61.1%). A median of three implants (range 1-5) was used per patient. The median hospital stay was 7.5 days (interquartile range 6.0-11.5), and eight patients (44.4%) required intensive care. Five patients (27.8%) had postoperative complications: pneumonia in three and reintervention associated with hemothorax in two. At follow-up, 10 of 15 patients (66.7%) reported no severe pain after discharge, six of 12 patients with a valid pain score (50.0%) were pain-free, and 10 of 15 (66.7%) were very satisfied with the treatment. Conclusions: In this small series, SSRF with a parallel-hook clamp system was performed mostly for multiple non-flail fractures and usually more than 72 hours after injury. Hospital stay and complication rates were within the ranges reported for SSRF, and most patients reported little residual pain. Without a control group, these findings cannot establish a benefit over nonoperative management.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-11-16
DOI
https://doi.org/10.7759/cureus.119779
Primary Topic
Trauma Management and Diagnosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Surgical Stabilization of Rib Fractures With a Parallel-Hook Clamp System: A Retrospective Case Series of 18 Patients From a Brazilian Hospital

Dante Adriano do Prado, Marcelo Rizon, Monica Celezinsky, Bruno D Alvarez et al.
1 links
Cureus
Trauma Management and Diagnosis
article

Surgical Stabilization of Rib Fractures With a Parallel-Hook Clamp System: A Retrospective Case Series of 18 Patients From a Brazilian Hospital

Dante Adriano do Prado, Marcelo Rizon, Monica Celezinsky, Bruno D Alvarez, Kerima D Cabrini
article en

Abstract

Introduction: Surgical stabilization of rib fractures (SSRF) is increasingly used for flail chest and severely displaced rib fractures, but data from Latin America on screwless clamp-type implants are scarce. This study describes the clinical profile, in-hospital outcomes, and patient-reported outcomes of patients who underwent SSRF with a parallel-hook clamp system. Methods: This retrospective case series included patients who underwent SSRF with a parallel-hook clamp system at a hospital in southern Brazil and who attended a follow-up visit and completed a structured interview. Data from medical records and interviews were analyzed descriptively, and missing data were not imputed. Results: Of 20 eligible patients, 18 were included (mean age 52.8 ± 13.4 years; 13 men, 72.2%). Car or motorcycle collisions caused 10 injuries (55.6%). A median of five ribs were fractured (range 1-7); 12 of 17 patients (70.6%) had multiple non-flail fractures, and three (17.6%) had flail chest. Twelve of 16 patients (75.0%) had a hemothorax or hemopneumothorax before surgery. Surgery was performed more than 72 hours after injury in 11 patients (61.1%). A median of three implants (range 1-5) was used per patient. The median hospital stay was 7.5 days (interquartile range 6.0-11.5), and eight patients (44.4%) required intensive care. Five patients (27.8%) had postoperative complications: pneumonia in three and reintervention associated with hemothorax in two. At follow-up, 10 of 15 patients (66.7%) reported no severe pain after discharge, six of 12 patients with a valid pain score (50.0%) were pain-free, and 10 of 15 (66.7%) were very satisfied with the treatment. Conclusions: In this small series, SSRF with a parallel-hook clamp system was performed mostly for multiple non-flail fractures and usually more than 72 hours after injury. Hospital stay and complication rates were within the ranges reported for SSRF, and most patients reported little residual pain. Without a control group, these findings cannot establish a benefit over nonoperative management.

Cureus
Hospital do Rocio (BR)
Good health and well-being
Trauma Management and Diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon